کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
1891038 | 1533500 | 2016 | 5 صفحه PDF | دانلود رایگان |
• A mobile electron beam irradiation system mounted on a trailer has developed.
• It is designed for treatment of wastewater and flue gas on site.
• Shielding of 0.7 MeV, 30 mA accelerator has done by a Monte Carlo technique.
• It can treat up to 500 m3/d of liquid waste at 2 kGy or 10,000 N m3/h of gas at 15 kGy.
Due to the necessity of pilot scale test facility for continuous treatment of wastewater and gases on site, a mobile electron beam irradiation system mounted on a trailer has developed. This mobile electron beam irradiation system is designed for the individual field application with self-shielded structure of steel plate and lead block which will satisfy the required safety figures of International Commission on Radiological Protection (ICRP). Shielding of a mobile electron accelerator of 0.7 MeV, 30 mA has been designed and examined by Monte Carlo technique. Based on a 3-D model of electron accelerator shielding which is designed with steel and lead shield, radiation leakage was examined using the Monte Carlo N-Particle Transport (MCNP) Code. Simulations with two different versions (version 4c2 and version 5) of MCNP code showed agreements within statistical uncertainties, and the highest leakage expected is 5.5061×10−01 (1±0.0454) μSv/h, which is far below the tolerable radiation dose limit for occupational workers. This unit could treat up to 500 m3 of liquid waste per day at 2 kGy or 10,000 N m3 of gases per hour at 15 kGy.
Journal: Radiation Physics and Chemistry - Volume 124, July 2016, Pages 174–178