کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1968484 1059721 2015 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Clinical, operational and economic outcomes of point-of-care blood gas analysis in COPD patients
موضوعات مرتبط
علوم زیستی و بیوفناوری بیوشیمی، ژنتیک و زیست شناسی مولکولی زیست شیمی
پیش نمایش صفحه اول مقاله
Clinical, operational and economic outcomes of point-of-care blood gas analysis in COPD patients
چکیده انگلیسی


• We evaluated the impact of POCT blood gas analysis versus clinical laboratory.
• Clinical, operational and economic outcomes were considered in COPD patients.
• There were discrepancies in the indication of LTOT in 13.4% of patients.
• TAT was measured considering the time from specimen collection to analysis report.
• The overall cost per process in POCT was 24.7% lower than that in laboratory.

IntroductionArterial blood gas analysis is relevant in chronic obstructive pulmonary disease (COPD) management. The aim of this study was to evaluate whether the use of a blood gas analyzer in pulmonology departments improves the clinical, operational and economic outcomes when compared with clinical laboratory measurements.Patients and methodsIt is an observational prospective study. 112 patients were selected. After specimen collection, the measurement was performed both in pulmonology office as point-of-care and in laboratory. We evaluated clinical outcomes (modification of the indication of long-term oxygen therapy (LTOT) according to results, changes in blood gas analysis results, relationship of the partial pressure of oxygen (PaO2) obtained in the medical visit and velocity of change of the PaO2, influence of total haemoglobin concentration and the change in PaO2), operational outcomes (turnaround time (TAT) from specimen collection to receiving the blood gas analysis report) and economic outcomes (overall cost per process of patient care).ResultsThere were discrepancies in the indication of LTOT in 13.4% of patients. All parameters showed changes. PaO2 levels showed changes in 2 ways, though they frequently increase over time. The correlation was not good in the other two clinical outcomes. The median TATs in pulmonology office were 1 min versus 79 in laboratory, with 52 min for specimen preparation and transport and 17 min for TAT intralaboratory. The overall cost for the 112 patients in pulmonology office and laboratory was 16,769.89€ and 22,260.97€ respectively.ConclusionsThe use of a blood gas analyzer in a pulmonology office improves clinical, operational and economic outcomes when compared with clinical laboratory.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Clinical Biochemistry - Volume 48, Issue 6, April 2015, Pages 412–418
نویسندگان
, , , , , , , , , ,