کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1968446 1538860 2016 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Validation of amino-acids measurement in dried blood spot by FIA-MS/MS for PKU management
ترجمه فارسی عنوان
اعتبارسنجی اندازه گیری آمینواسیدها در نقطه خون خشک شده توسط FIA-MS/MS برای مدیریت PKU
موضوعات مرتبط
علوم زیستی و بیوفناوری بیوشیمی، ژنتیک و زیست شناسی مولکولی زیست شیمی
چکیده انگلیسی


• We developed a rapid method with excellent performances.
• We evaluated Tyr, Leu and Val concentrations in PKU.
• We determined normal references that are similar to references ranges published by different studies.
• We observed that 50% of PKU patients had lower concentrations of Tyr, Leu and/or Val.

ObjectivesPhenylketonuria (PKU) is a metabolic disorder leading to high concentrations of phenylalanine (Phe) and low concentrations of tyrosine (Tyr) in blood and brain that may be neurotoxic. This disease requires a regular monitoring of plasma Phe and Tyr as well as branched-chain amino-acids concentrations to adapt the Phe-restricted diet and other therapy that may be prescribed in PKU. We validated a Flow Injection Analysis tandem Mass Spectrometry (FIA-MS/MS) to replace the enzymatic method routinely used for neonatal screening in order to monitor in parallel to Phe, Tyr and branched-chain amino-acids not detected by the enzymatic method.Design and methodsWe ascertained the performances of the method: linearity, detection and quantification limits, contamination index, accuracy. We cross validated the FIA-MS/MS and enzymatic methods and we evaluated our own reference ranges to monitor Phe, Tyr, Leu, Val on 59 dried blood spots of normal controls. We also evaluated Tyr, Leu and Val concentrations in PKU patients to detect some potential abnormalities, not evaluated by the enzymatic method.ResultsWe developed a rapid method with excellent performances including precision and accuracy < 15%. We noted an excellent correlation of Phe concentrations between FIA-MS/MS and enzymatic methods (p < 0.0001) based on our database which are similar to references ranges published. We observed that 50% of PKU patients had lower concentrations of Tyr, Leu and/or Val that could not be detected by the enzymatic method.ConclusionBased on laboratory accreditation recommendations, we validated a robust, rapid and reliable FIA-MS/MS method to monitor plasma Phe concentrations but also Tyr, Leu and Val concentrations, suitable for PKU management. We evaluated our own reference ranges of concentration for a routine application of this method.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Clinical Biochemistry - Volume 49, Issues 13–14, September 2016, Pages 1047–1050
نویسندگان
, , , , , , , , , , ,