کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
207331 461213 2010 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Influence of outer secondary-air vane angle on combustion characteristics and NOx emissions of a down-fired pulverized-coal 300 MWe utility boiler
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی مهندسی شیمی (عمومی)
پیش نمایش صفحه اول مقاله
Influence of outer secondary-air vane angle on combustion characteristics and NOx emissions of a down-fired pulverized-coal 300 MWe utility boiler
چکیده انگلیسی

Industrial experiments were performed on a down-fired pulverized-coal 300 MWe utility boiler with swirl burners. Gas temperature, concentrations of gas components (O2, CO, CO2 and NOx) in the burning region and carbon content in the fly ash were measured with outer secondary-air vane angles of 25°, 32.5° and 50°. Results indicate that with increasing vane angle, NOx emission and boiler efficiency decrease. Overall evaluation boiler efficiency and NOx emission, the vane angle of 32.5° is optimum. Using an IFA300 constant-temperature anemometer system, cold air experiments on a quarter-scaled burner model were also carried out to investigate the influence of various outer secondary-air vane angles on the flow characteristics in the burner nozzle region. No central recirculation zone appeared for vane angles of 25° and 32.5°. Most of the pulverized-coal was ignited in the external recirculation zone. For vane angles of 45° and 55°, a central recirculation zone could be observed, and air flow rigidity and axial velocities decreased rapidly.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Fuel - Volume 89, Issue 7, July 2010, Pages 1525–1533
نویسندگان
, , , , ,