کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2083515 1545337 2014 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Physiological relevant in vitro evaluation of polymer coats for gastroretentive floating tablets
ترجمه فارسی عنوان
ارزیابی فیزیولوژیکی در شرایط آزمایشگاهی از پوششهای پلیمری برای قرصهای شناور ناپایدار
موضوعات مرتبط
علوم زیستی و بیوفناوری بیوشیمی، ژنتیک و زیست شناسی مولکولی بیوتکنولوژی یا زیست‌فناوری
چکیده انگلیسی


• Important properties of CO2 developing bilayer tablets were characterised in vitro.
• Impact of mechanical stress and pH on drug release and floating force was studied.
• Physiological relevant dissolution stress test with pulsed pressures was also used.
• Polyvinyl acetate and ammonio-methacrylate type A coatings were compared.

Gastroretentive drug delivery systems are retained in the stomach for a sufficient time interval, releasing the drug in a controlled manner. According to literature, the floating principle is the most frequently used formulation approach for gastric retention. However, many publications lack information of the floating forces, the impact of different pH-values and almost no information exist concerning the resistance of the floating performance against physiological relevant stress. Therefore, we evaluated the performance of CO2-generating floating bilayer (drug and floating layer) tablets with respect to robustness, drug release profile, pH dependence and floating behaviour. Bilayer tablets were coated with a flexible and water permeable, but CO2-retaining polymer film of either polyvinyl acetate or ammonio-methacrylate copolymer type A. Metformin-HCl was used as a relevant model drug due to its dose-dependent and saturable absorption from the proximal part of the small intestine. To mimic physiological relevant mechanical stress conditions, recently developed dissolution stress tests with pulsed pressures were applied in addition to release studies according to the pharmacopeia.Bilayer tablets coated with polyvinyl acetate showed short floating lag times, reasonable floating strength values, floating durations of more than 24 h in simulated gastric fluid and a robust and pH independent release of Metformin-HCl. Tablets coated with ammonio-methacrylate copolymer type A showed a higher permeability for the active ingredient combined with a decreased robustness of the inflated tablets. Both polymers can be used for balloon-like floating devices. The appropriate polymer has to be chosen dependent from the properties of the active ingredient and requested application of the delivery device. Furthermore, the dissolution stress test analysis is able to indicate possible safety issues of gastroretentive formulations as well as to characterise the robustness of formulation principles towards mechanical stresses of bio-relevant intensity.

Figure optionsDownload high-quality image (168 K)Download as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: European Journal of Pharmaceutics and Biopharmaceutics - Volume 88, Issue 3, November 2014, Pages 778–786
نویسندگان
, , ,