کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2160229 1090876 2008 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Analysis of prostate-specific antigen bounce after I125 permanent seed implant for localised prostate cancer
موضوعات مرتبط
علوم زیستی و بیوفناوری بیوشیمی، ژنتیک و زیست شناسی مولکولی تحقیقات سرطان
پیش نمایش صفحه اول مقاله
Analysis of prostate-specific antigen bounce after I125 permanent seed implant for localised prostate cancer
چکیده انگلیسی

Background and purposeTo report on the incidence of benign prostate-specific antigen bounce following permanent I125 prostate brachytherapy, to describe the associations in our population and review the relationship of bounce to subsequent biochemical failure.Materials and methodsFrom February 2000 to May 2005, 374 patients with localised prostate cancer were treated with I125 permanent prostate brachytherapy at a single institution. A prospectively collected database was used to identify cases of prostate-specific antigen (PSA) bounce, defined as a rise of ⩾0.2 ng/ml above an initial PSA nadir with subsequent decline to or below that nadir without treatment. The patients who received neo-adjuvant or adjuvant hormone manipulation were excluded. Biochemical failure was determined using the both the ASTRO consensus definition and Phoenix (nadir +2 ng/mL) definition.ResultsTwo hundred and five patients were identified with a median follow-up of 45 months (24–85). PSA bounce was noted in 79 (37%) men, occurring at a median of 14.8 months (1.7–40.6) following implant. The median peak PSA was 1.8 ng/ml (0.4–7.4) with a bounce magnitude of 0.91 ng/ml (0.2–5.8). When pre- and post-implant factors were assessed for association to bounce, only younger age was statistically significant (p = 0.002). The threshold for biochemical failure as defined by the ASTRO consensus definition (1997) was met in 4 (5%) patients after experiencing bounce as opposed to 19 (15%) non-bounce patients (p = 0.01).The threshold for Phoenix (nadir +2 ng/mL) was met in 6 (7.5%) patients following bounce versus 22 (17%) of non-bounce patients (p = 0.003). Both definitions are prone to false positive calls during bounce.Median PSA velocity during the bounce was 0.08 ng/mL/month (0.02–0.98) and was statistically significantly lower than the median velocity prior to the Phoenix biochemical failure at 0.28 ng/mL/month (0.07–2.04) (p = 0.0005).ConclusionPSA bounce is a common finding in our population and is associated with a lower rate of subsequent biochemical failure. The noted differences in PSA velocity will require verification in a future analysis to reduce the influence of median follow-up on this finding. Patients should be advised of the potential of bounce in PSA follow-up after permanent I125 prostate brachytherapy and physicians involved in follow-up of prostate brachytherapy patients should be aware of this phenomenon, allowing them to commit to appropriate PSA surveillance, avoiding the premature and inappropriate initiation of salvage therapy during PSA bounce.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Radiotherapy and Oncology - Volume 88, Issue 1, July 2008, Pages 102–107
نویسندگان
, , , , , ,