کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
247708 502516 2016 12 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Multizone air leakage measurements and interactions with ventilation flows in low-energy homes
ترجمه فارسی عنوان
اندازه گیری های نشت هوای ملتوزون و تعامل با جریان تهویه در خانه های کم انرژی
کلمات کلیدی
تهویه نشت هوا، اندازه گیری، خانه های تک خانواده، کیفیت هوا در داخل
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی های تجدید پذیر، توسعه پایدار و محیط زیست
چکیده انگلیسی


• We performed 456 exterior and internal partition wall air leakage measurements.
• We develop an index reliability and 63% of the data has a 100% reliability index.
• We show that internal air leakage is significant compared to door undercuts.
• Our measurements contradict the assumption that leakage is uniformly distributed.
• We suggest input values for multizone airflow modelling.

Given that airtightness is recognized as an essential issue for low-energy dwellings, today it is often included in energy performance (EP) calculations, frequently through single-zone models with uniform air leakage. Because more consideration is often given to EP than to indoor air quality issues, air leakage through internal partitions is often disregarded. Therefore, additional studies are needed to check these assumptions.In the present study air leakage through the building envelope and through internal partitions is investigated. This paper presents the methodology used in an experimental study, conducted to measure multizone air leakages, using the guarded zone pressurization technique. We developed a detailed innovative database with 456 exterior and internal partition wall air leakage measurements, taken in 23 detached houses. For each wall, the database includes general information on the building, special requirements, the building's main characteristics, measurement protocol, type of wall, measurement input data and measurement results (CL, n, q50 and the reliability index developed). Then an analysis of this database is provided. The analysis reveals most important relationships. For instance, internal partition wall air leakage is not related to the envelope's airtightness level; instead, the type of building structure has greater influence. Through this study, we underline the impact on building airflows of more detailed modelling of internal and external air leakage in multizone approaches, with consequences on indoor air quality (IAQ) bedrooms where people spend most of their time. As a conclusion, we propose air leakage values and dispersion input data for multizone IAQ models.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Building and Environment - Volume 107, October 2016, Pages 52–63
نویسندگان
, , , , , ,