کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
248412 502564 2013 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Comparison of environmental and acoustic factors in occupied school classrooms for 11–16 year old students
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی های تجدید پذیر، توسعه پایدار و محیط زیست
پیش نمایش صفحه اول مقاله
Comparison of environmental and acoustic factors in occupied school classrooms for 11–16 year old students
چکیده انگلیسی

This paper analyses and compares environmental and acoustic measurements taken from 12 contrasting schools in England. The 203 classrooms measured ranged in age, style (open plan, semi-open plan and cellular) and external noise levels. The occupied environmental measures were: CO2 count, relative humidity, temperature and light intensity. The occupied acoustic measures taken were: LAeq, L1, L10 and L90. In addition, ventilation strategy, room dimensions and student numbers were also recorded. Lesson averages were compared to remove fluctuations observed in some parameters during lessons. Large variations in CO2 levels were observed between schools with 39% exceeding recommended guidelines. Lighting levels were predominantly below the recommended level required for demanding tasks. Classrooms with mechanical ventilation had higher background noise levels than those using natural ventilation. Most environmental parameters were uncorrelated with acoustic parameters. A notable exception was the correlation between LAeq and CO2 count; due to the relationships between these parameters, number of students and classroom floor area. A regression model was produced predicting a doubling in LAeq, with a 67% increase in student numbers.


► Comparison and analysis of environmental and acoustic measurements from 12 schools in England.
► Large variations in CO2 levels were observed between schools with some exceeding recommended guidelines.
► Lighting levels were predominantly below the recommended level required for demanding tasks.
► Classrooms with mechanical ventilation had higher background noise levels than those using natural ventilation.
► A regression model was produced predicting a doubling in LAeq, with a 167% increase in student numbers.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Building and Environment - Volume 60, February 2013, Pages 265–271
نویسندگان
, , , , , ,