چکیده انگلیسی

ObjectiveExposure to organophosphates (OP) may lead to a life threatening cholinergic crisis with death attributed to a rapidly progressive respiratory failure. In a toxicological mass casualty event involving organophosphate exposure, many of the victims may depend on immediate short-term ventilation to overcome the respiratory distress which may exhaust life supporting resources. In addition, the mandatory use of personal protective gear by first responders emphasizes the need for a noninvasive, easy-to-operate ventilation device. Our objective was to assess the efficacy of MRTX, a Biphasic Cuirass Ventilation device, in comparison with standard bag-valve mask ventilation following acute organophosphate poisoning.MethodsPigs were exposed to paraoxon poisoning (1.4 LD50), and treated 8 min later with atropine (0.05 mg/kg). The control group received no further support (n = 9), the two experimental groups received ventilation support initiated 15 min post exposure and lasted for 25 min: one group was ventilated with the commonly used bag-valve mask (Mask group, n = 7) and the other was ventilated with the Biphasic Cuirass Ventilation device (Cuirass group, n = 7). Clinical signs and physiological parameters were monitored during the first hour, and mortality up to 24 h post exposure was recorded.ResultsNo mortality was observed in the Cuirass group following OP poisoning, while mortality in the Control and in the Mask groups was high (67% and 71%, respectively). Mouth excretions of the cuirass-ventilated animals were frothy white as in deep suctioning, as opposed to the clear saliva-like appearance of secretions in the other two groups. No further group differences were recorded.ConclusionsThe noninvasive, easy-to-operate Biphasic Cuirass Ventilation device was effective in reducing OP-induced mortality and might be advantageous in an organophosphate mass casualty event. This finding should be validated in further investigations.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Toxicology Reports - Volume 2, 2015, Pages 40–45
نویسندگان
, , , , , , , ,