کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2596341 1132522 2010 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Comparative assessment of the sensory irritation potency in mice and rats nose-only exposed to ammonia in dry and humidified atmospheres
موضوعات مرتبط
علوم زیستی و بیوفناوری علوم محیط زیست بهداشت، سم شناسی و جهش زایی
پیش نمایش صفحه اول مقاله
Comparative assessment of the sensory irritation potency in mice and rats nose-only exposed to ammonia in dry and humidified atmospheres
چکیده انگلیسی

Young adult male Wistar rats, a species commonly used in inhalation toxicity studies, and OF1 mice, a species often used in sensory irritation studies, were simultaneously nose-only exposed for 45-min to ammonia in concentrations from 92 to 1243 mg/m3. This study examined airway reflexes by the changes in respiratory patterns elicited by ammonia in either dry, steam-humidified (approximately 95% relative humidity) or aqueous aerosol containing atmospheres. This served the objective to explore whether high concentrations of anhydrous ammonia and/or high humidity and aqueous aerosol change the predominant nasal deposition site to more distal locations in the lung. Animals from all groups tolerated the exposure without evidence of respiratory tract irritation, changes in body and lung weights. The evoked changes on breathing patterns resembled those known to occur following exposure to ‘upper respiratory tract sensory irritants’, rapid in onset and reversibility. Reflex stimulation from the lower airways was not observed in any group. While mice showed some adaption during the 45-min exposure period, rats displayed more stable changes in respiratory patterns. In this species humidity- or aqueous aerosol-related changes in sensory irritation potency did not occur to any appreciable extent. The respiratory decrease 50%, RD50, was 972 and 905 mg/m3 in dry and wet air, respectively. In contrast, mice appeared to more susceptible to ammonia in presence of dry air (the RD50, was 582 and 732 mg/m3 in dry and wet air, respectively). In summary, it was shown that the sensory irritation potency of ammonia does not increase when inhaling wet atmospheres nor penetrates this gas into the lower airways up to 1243 mg/m3 × 45-min. The mild-to-moderate sensory irritation-related effects observed at ≈400 mg/m3 (571 ppm) × 45-min do not appear to be offensive enough to impair escape as a result of upper airway sensations. Interestingly, this rat-based estimate matches almost exactly the experienced-based RAM TRAC recommendations of 696 and 492 ppm for 30 and 60 min, respectively.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Toxicology - Volume 276, Issue 2, 9 October 2010, Pages 135–142
نویسندگان
, ,