The misunderstanding of the overall behaviour of traditional timber trusses can result in incorrect strengthening interventions or, frequently, on their replacement. Timber roof structures need a more concise knowledge of the real behaviour to determine internal loads and control the load transfer. For that, laboratory tests on scaled or full-scale specimens of members, connections and trusses are needed.In this paper, an accurate geometric and mechanical evaluation of the timber elements of two King-post timber trusses, based on grading results with data gathered from non-destructive tests (NDT), including mechanical evaluation of the modulus of elasticity in bending (MoE), followed by full-scale carrying tests were performed. The trusses were reassembled in laboratory and submitted to a series of symmetric and non-symmetric cyclic tests, according to the Limit States. Strengthening techniques evaluated in precedent research steps were used in a second phase of the load-carrying tests.
Journal: Construction and Building Materials - Volume 24, Issue 3, March 2010, Pages 371–383