کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2621612 1135702 2007 12 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Three-Dimensional Manual Contact Force Evaluation of Graded Perpendicular Push Force Delivery by Second-Year Physiotherapy Students During Simple Feedback Training
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی طب مکمل و جایگزین
پیش نمایش صفحه اول مقاله
Three-Dimensional Manual Contact Force Evaluation of Graded Perpendicular Push Force Delivery by Second-Year Physiotherapy Students During Simple Feedback Training
چکیده انگلیسی

ObjectiveThe purpose of this study was to investigate a quantitative biomechanical evaluation method for contact forces exerted during a manual examination and treatment technique used in a learning environment. The evaluation was based on three-dimensional (3D) force component data.MethodsA hand-/palm-held computerized 3D force component measuring system was used during a simple feedback experiment involving 20 second-year university students of physiotherapy who delivered 5 sets of graded perpendicular manual push forces on the sensor part of the system, which was placed on the padded surface of an examination/treatment table. In an effect study with a multiple time-series design, a randomly chosen subgroup of subjects received concurrent visual 3D kinetic/dynamic force–time feedback.ResultsThe students delivered graded perpendicular forces with good intrasubject consistency (intraclass correlation coefficient [3, 1]: mean, 0.80; range, 0.76-0.88) but with poor intersubject consistency (intraclass correlation coefficient [2, 1]: mean, 0.38; range, 0.15-0.74). A temporary performance improvement in forward-backward force direction deviations from the perpendicular in the subgroup given feedback indicates that students are sensitive to feedback training.ConclusionAn evaluation tool using 3D contact force component measurement enables the assessment of the overall magnitude of the manual contact force as well as its directional aspect. Compared with existing evaluations based on 1-dimensional force components, this 3D system allows for a more complete and, at the same time, more specific quantitative evaluation of the manual contact forces. Three-dimensional dynamic/kinetic augmented feedback has the additional potential of helping students and practitioners to improve their palpation and force delivery skills.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Manipulative and Physiological Therapeutics - Volume 30, Issue 6, July 2007, Pages 438–449
نویسندگان
, , ,