کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
264377 504099 2011 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Thermal performance analysis according to wood flooring structure for energy conservation in radiant floor heating systems
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی های تجدید پذیر، توسعه پایدار و محیط زیست
پیش نمایش صفحه اول مقاله
Thermal performance analysis according to wood flooring structure for energy conservation in radiant floor heating systems
چکیده انگلیسی

The aim of this study was to reduce energy consumption, especially heating, in buildings. Improvements in the thermal conductivity of wood flooring, which was considered to decrease heating between floors and the indoor areas, were investigated. Wood flooring components such as solid-wood, high-density fiberboard (HDF), adhesives and polyethylene generally exhibit low thermal conductivity. The thermal conductivity and transfer performance of 21 replicates of wood flooring materials generally used in Korea were measured. The thermal conductivity was measured by using the guarded hot plate method. The thermal conductivities differed according to the structure of the floorings. Laminate wood flooring exhibited the highest thermal conductivity because of its high density and thin layers compared to the other floorings. The thermal transfer performance differed according to the installation method. The floating installation method exhibited a lower thermal transfer speed than the adhesion installation method because of its air layers and polyethylene form.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Energy and Buildings - Volume 43, Issue 8, August 2011, Pages 2039–2042