ObjectivesTo test the validity and intra-instrument reliability of the HJ-203 Omron pedometer when worn in different positions, under controlled and free-living conditions.DesignCross-sectional.MethodsForty healthy adults (20 men, 29.5 ± 7.7 years) participated in three controlled tests, i.e. 20 step test, stair climbing (up and down), and treadmill walking (five bouts at different speeds). All participants wore a HJ-203 pedometer in the pants pocket, in a carrier bag, and around the neck. Fifty-four adults (23 men, 33.9 ± 11.1 years) participated in a free-living conditions test, wearing a HJ-203 in the pants pocket and around the neck during one day.ResultsDuring controlled tests, absolute percentage error ranged between 0.1% and 14.0%. Accuracy was influenced by wearing position (p < 0.001), walking speed (p < 0.001), and wearing position × walking speed (p = 0.001). Accuracy was poor for pedometers worn in the pants pocket, especially at slower speeds; and best when worn around the neck. During free-living conditions, APE ranged between 30.7% and 36.9% and did not differ statistically between pants pocket and neck position. Intra-instrument reliability varied for controlled tests (ICC = 0.14–0.96) and was acceptable during free-living conditions (ICC = 0.94).ConclusionsThe HJ-203 Omron pedometer showed acceptable accuracy for all wearing positions during stairs walking and treadmill walking at higher speeds; but limited accuracy during free-living conditions when worn at non-traditional wearing positions (necklace and pants pocket). Reliability was acceptable during treadmill walking at higher speeds and free-living conditions.
Journal: Journal of Science and Medicine in Sport - Volume 15, Issue 5, September 2012, Pages 418–424