Numerical analysis of MD events and preliminary thermal calculation for KTX vacuum vessel
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
پیش نمایش صفحه اول مقاله
Numerical analysis of MD events and preliminary thermal calculation for KTX vacuum vessel
چکیده انگلیسی


• To verify design strength, EM and mechanical analysis was implemented.
• During MD events, the radial force due to large eddy current is predominant.
• We confirmed the VV structure is still strong enough even in the most severe condition.
• Preliminary thermal calculation suggested suitable discharge parameters.

KTX is a new reversed field pinch (RFP) magnetic confinement device which is under design in ASIPP and USTC. Major disruption (MD) events may occur in future operating process, which is simulated with the finite element (FE) method. The results present that the peaks of eddy currents on vessel and conductor shell are respectively 11.791 kA and 68.637 kA with maximum stress 67.1 MPa due to high transient electromagnetic (EM) force. It is confirmed that the structure is still strong enough to bear the electromagnetic loads even if the worst case. Besides, as KTX vacuum vessel will take the method of natural cooling for heat dissipation during plasma discharge (0.5–1.0 MA), a preliminary thermal calculation was implemented in normal condition to decide suitable time parameters such as duration and interval. It is suggested that the discharge interval should be no less than 5 min for the complete 1 MA plasma with 100 ms duration, which can guarantee the temperature of vacuum vessel below 200 °C.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Fusion Engineering and Design - Volume 88, Issue 12, December 2013, Pages 3180–3184
نویسندگان
, , , , , , , , , , ,