کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
272324 | 505018 | 2010 | 4 صفحه PDF | دانلود رایگان |
![عکس صفحه اول مقاله: Time accuracy requirements for fusion experiments: A case study at ASDEX Upgrade Time accuracy requirements for fusion experiments: A case study at ASDEX Upgrade](/preview/png/272324.png)
To manage and operate a fusion device and measure meaningful data an accurate and stable time is needed. As a benchmark, we suggest to consider time accuracy as sufficient if it is better than typical data errors or process timescales. This allows to distinguish application domains and chose appropriate time distribution methods. For ASDEX Upgrade a standard NTP method provides Unix time for project and operation management tasks, and a dedicated time system generates and distributes a precise experiment time for physics applications. Applying the benchmark to ASDEX Upgrade shows that physics measurements tagged with experiment time meet the requirements, while correlation of NTP tagged operation data with physics data tagged with experiment time remains problematic. Closer coupling of the two initially free running time systems with daily re-sets was an efficient and satisfactory improvement. For ultimate accuracy and seamless integration, however, continuous adjustment of the experiment time clock frequency to NTP is needed, within frequency variation limits given by the benchmark.
Journal: Fusion Engineering and Design - Volume 85, Issues 3–4, July 2010, Pages 356–359