کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
272514 | 505025 | 2011 | 4 صفحه PDF | دانلود رایگان |

Recent experimental data from the ITER critical heat flux (CHF) mock-ups was used to benchmark a 3D CFD code concerning subcooled boiling heat transfer for high heat flux removal. The predicted temperatures show good agreement with experimental measurements for a range of operating parameters and of cooling configurations. Specifically, it applies to a hypervapotron channel exposed to a 5 MW/m2 surface heat load and cooled by velocity of 2 m/s. Such flow geometry and operating condition seem necessary for ITER-enhanced heat flux first wall modules if an adequate design margin in CHF is needed. A detailed CFD and heat transfer analysis performed on a prototyped CAD model provided a higher confidence on the design and is deemed a desirable feature for continued design exploration and optimization processes. This is particularly crucial in regard to flow distribution among the FW fingers.
Journal: Fusion Engineering and Design - Volume 86, Issues 6–8, October 2011, Pages 667–670