کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
273403 505044 2009 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Design and testing of ITER ECH & CD transmission line components
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
پیش نمایش صفحه اول مقاله
Design and testing of ITER ECH & CD transmission line components
چکیده انگلیسی

Initial testing on the Japan Atomic Energy Agency Gyrotron Test Stand of ITER-relevant TL components, has shown reasonable efficiencies, but identified that trapped modes between closely located miter bends, as well as mode conversion at miter bends can lead to excessive heating of the connecting waveguides. General Atomics has designed, built, and will test components to address this issue as well as ITER relevant components that have not been tested at the levels of 1 MW, 170 GHz, for extended pulse lengths. Some of the components that will be tested are ultra low loss miter bends, dc breaks, polarizers, power monitors, bellows, waveguide switches, waveguide cooling clamps, etc. Details of the components and test results will be presented.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Fusion Engineering and Design - Volume 84, Issues 2–6, June 2009, Pages 526–529
نویسندگان
, , , , , , , , , ,