کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
273555 505048 2007 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
High heat flux tests of the WENDELSTEIN 7-X pre-series target elements: Experimental evaluation of the thermo-mechanical behaviour
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
پیش نمایش صفحه اول مقاله
High heat flux tests of the WENDELSTEIN 7-X pre-series target elements: Experimental evaluation of the thermo-mechanical behaviour
چکیده انگلیسی

The high heat flux (HHF) testing of WENDELSTEIN 7-X pre-series target elements is an indispensable step in the qualification of the manufacturing process. A set of 20 full scale pre-series elements was manufactured by PLANSEE SE to validate the materials and manufacturing technologies prior to the start of the series production.The HHF tests were performed in the ion beam test facility GLADIS. All actively water-cooled elements were tested for about 100 cycles at 10 MW/m2 (10–15 s pulse duration). Several elements were loaded with even higher cycle numbers (up to 1000) and heat loads up to 24 MW/m2. Hot spots were, observed at the edges of several tiles during the HHF tests indicating local bonding problems of the CFC.The thermo-mechanical behaviour under HHF loading has been evaluated and compared to the FEM predictions. The measured temperatures and strains confirm the chosen FEM approach. This allows a component optimisation to achieve a successful series production of the W7-X divertor target elements.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Fusion Engineering and Design - Volume 82, Issues 15–24, October 2007, Pages 1713–1719