کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
273891 505069 2006 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Preliminary transient thermal analysis for safety of the dual-cooled waste transmutation blanket for the FDS-I
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
پیش نمایش صفحه اول مقاله
Preliminary transient thermal analysis for safety of the dual-cooled waste transmutation blanket for the FDS-I
چکیده انگلیسی

The dual-cooled waste transmutation (DWT) blanket is one of the key components of the fusion-driven subcritical system (FDS-I). Because of the large energy gain, the heat removal in accidents remains a major safety concern. In this contribution, several representative transients such as unprotected loss of flow accident in helium gas and LiPb (ULOFA), protected loss of flow accident in helium gas and LiPb (LOFA) and loss of power accident (LOPA) are calculated and analyzed. The blanket will not melt until several hours if the plasma core is shut down in time when the accidents occur. It has enough time to start additional action to keep the system safety. The results show that passive solution to shut down the plasma shall be given due to the little scale of responding time. Also, the results show an effective active heat removal solution such as liquid metal (LM) drain system and emergency blanket cooling system is needed.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Fusion Engineering and Design - Volume 81, Issues 8–14, February 2006, Pages 1397–1401
نویسندگان
, , , , ,