کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2760445 1150173 2010 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Weaning Mechanical Ventilation After Off-Pump Coronary Artery Bypass Graft Procedures Directed by Noninvasive Gas Measurements
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی بیهوشی و پزشکی درد
پیش نمایش صفحه اول مقاله
Weaning Mechanical Ventilation After Off-Pump Coronary Artery Bypass Graft Procedures Directed by Noninvasive Gas Measurements
چکیده انگلیسی

Objective(s)Partial pressure of carbon dioxide and oxygen were transcutaneously measured in adults after off-pump coronary artery bypass (OPCAB) surgery. The clinical use of such measurements and interchangeability with arterial blood gas measurements for weaning patients from postoperative mechanical ventilation were assessed.DesignThis was a prospective observational study.SettingTertiary referral heart hospital.ParticipantsPostoperative OPCAB surgical patients.InterventionsTranscutaneous oxygen and carbon dioxide measurements.Measurements and Main ResultsIn this prospective observational study, 32 consecutive adult patients in a tertiary care medical center underwent OPCAB surgery. Noninvasive measurement of respiratory gases was performed during the postoperative period and compared with arterial blood gases. The investigator was blinded to the reports of arterial blood gas studies and weaned patients using a “weaning protocol” based on transcutaneous gas measurement. The number of patients successfully weaned based on transcutaneous measurements and the number of times the weaning process was held up were noted. A total of 212 samples (pairs of arterial and transcutaneous values of oxygen and carbon dioxide) were obtained from 32 patients. Bland-Altman plots and mountain plots were used to analyze the interchangeability of the data. Twenty-five (79%) of the patients were weaned from the ventilator based on transcutaneous gas measurements alone. Transcutaneous carbon dioxide measurements were found to be interchangeable with arterial carbon dioxide during 96% of measurements, versus 79% for oxygen measurements.ConclusionMore than three fourths of the patients were weaned from mechanical ventilation and extubated based on transcutaneous gas values alone after OPCAB surgery. The noninvasive transcutaneous carbon dioxide measurement can be used as a surrogate for arterial carbon dioxide measurement to manage postoperative OPCAB patients.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Cardiothoracic and Vascular Anesthesia - Volume 24, Issue 3, June 2010, Pages 451–455
نویسندگان
, , , , ,