کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2762135 1567657 2016 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Does laryngoscopic view after intubation predict laryngoscopic view before intubation? ★
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی بیهوشی و پزشکی درد
پیش نمایش صفحه اول مقاله
Does laryngoscopic view after intubation predict laryngoscopic view before intubation? ★
چکیده انگلیسی


• The main finding of this study was the endotracheal tube altered the MCL in 33% of patients.
• BURP improved views before intubation but not in the presence of the endotracheal tube.
• Postintubation MCL grades may not be reliable to predict future laryngeal grades.

Study objectiveTo determine if an endotracheal (ET) tube will distort the laryngeal view obtained with direct laryngoscopy measuring with the modified Cormack-Lehane scale (MCL).DesignObservational single-arm study.SettingThe University of Calgary teaching hospitals.PatientsPatients between 18 and 86 years of age undergoing elective surgical procedures. A total of 173 patients were enrolled and analyzed.InterventionsDirect laryngoscopy view obtained before ET intubation and directly after intubation.Measurements and resultsThe MCL scales were described for each view obtained and compared to each other with each patient serving as their own control. The primary objective was a change in the best obtainable view by direct laryngoscopy from an acceptable view (MCLS 1 or 2a) to an unacceptable view (MCLS 2b, 3, or 4) or changing from an unacceptable view (MCLS 2b, 3, or 4) to an acceptable view (MCLS 1 or 2a). The main finding of this study was that the ET tube altered the MCL in 58 (33%) of 173 patients, “worsening” the grade in 30 patients (17.34%) and “improving” the grade in 28 patients (16.18%).ConclusionsWe performed a prospective observational study to address the predictive value of postintubation laryngoscopy grade in adults. The presence of the ET tube both increased visualization of the glottis and worsened the view in different subjects. The important outcome was that the presence of the ET tube did in fact change the view obtained of the larynx during direct laryngoscopy. In conclusion, postintubation MCL grades may not be reliable to predict laryngeal grade and should be used with caution in the right clinical context.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Clinical Anesthesia - Volume 33, September 2016, Pages 469–475
نویسندگان
, , , , ,