کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2804601 1156884 2010 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Modified orthostatic load for spectral analysis of short-term heart rate variability improves the sensitivity of autonomic dysfunction assessment
موضوعات مرتبط
علوم زیستی و بیوفناوری بیوشیمی، ژنتیک و زیست شناسی مولکولی علوم غدد
پیش نمایش صفحه اول مقاله
Modified orthostatic load for spectral analysis of short-term heart rate variability improves the sensitivity of autonomic dysfunction assessment
چکیده انگلیسی

AimTo evaluate the impact of orthostatic load for sensitivity of short-term spectral analysis of heart rate variability (HRV) assessment of potential early autonomic dysfunction in diabetes mellitus.MethodsComparison of results of short-term time- and frequency-domain analysis of HRV during single positions and during modified orthostatic load (supine 1–standing–supine 2, each position 300 s) in diabetic subjects with good glycemic control (n=80, age 38±14, diabetes duration 16±10 years) and without autonomic neuropathy as assessed by a standard bedside reflex test battery, and in nondiabetic controls (n=150, age 40±13 years).ResultsNone of the short-term frequency-domain parameters [absolute and logarithmic (LN) values of spectral powers in total- (TF), low- (LF), and high-frequency (HF) bands and its centroid frequencies] as obtained in single positions “supine” or “standing” revealed a significant difference between well-controlled patients and healthy controls (P>.3). However, during modified orthostatic load, significant differences in ΔLN TF(supine 1–supine 2) and in ΔLN LF(supine 1–supine 2) as well as in ΔLN LF(standing–supine 2) values between diabetic and healthy subjects were recorded [−0.2±0.5 vs. −0.1±0.4 LN (ms2), P=.05; −0.3±0.8 vs. 0.1±0.7 LN (ms2), P=.001 and 0.2±1.0 vs. 0.4±0.9 LN (ms2), P=.05, respectively] with insignificant intergroup differences in related centroid frequencies. This finding suggests a delayed recovery of LF spectral power in diabetic subjects after orthostatic challenge.ConclusionsWhen compared with single position measurements, the modified orthostatic load protocol improves the sensitivity of short-term HRV examination. In well-controlled diabetic subjects without cardiovascular autonomic neuropathy (as excluded by standard cardiovascular reflex testing), the delayed recovery of LF band spectral power after orthostatic load with standing up indicates diminished parasympathetic activation.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Diabetes and its Complications - Volume 24, Issue 1, January–February 2010, Pages 48–54
نویسندگان
, , , , ,