کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2840498 1165325 2013 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
In search of magnetosensitivity and ferromagnetic particles in Rhodnius prolixus: Behavioral studies and vibrating sample magnetometry
موضوعات مرتبط
علوم زیستی و بیوفناوری علوم کشاورزی و بیولوژیک دانش حشره شناسی
پیش نمایش صفحه اول مقاله
In search of magnetosensitivity and ferromagnetic particles in Rhodnius prolixus: Behavioral studies and vibrating sample magnetometry
چکیده انگلیسی

Magnetoreception is a sensory mechanism with wide phylogenetic distribution, which many organisms use for navigation and orientation. Radical pair reactions and the use of magnetic particles have been proposed as mechanisms for magnetosensitivity in terrestrial animals. Magnetosensitivity and the presence of a ferromagnetic material were tested in the hematophagous bug Rhodnius prolixus (Hemiptera: Reduviidae: Triatominae) vector of Chagas disease in Colombia and Venezuela. R. prolixus is well known in both countries for its active dispersal that allows flow of individuals from sylvatic to domestic environments.Behavioral experiments quantifying the number of body rotations and quadrant changes in a Petri dish were carried out, applying 1 mT artificial field in a constant direction for 45 min and rotated 180° every 5 min for 45 min. In addition, magnetite presence in the abdomens of Apis mellifera (positive control) and the bodies of R. prolixus was tested using a vibrating sample magnetometer (VSM).No differences in the number of body rotations and quadrant changes were found in R. prolixus with and without the presence of an artificial magnetic field. Results obtained with the VSM indicate presence of ferromagnetic material (hysteresis loop) in A. mellifera abdomens and absence of ferromagnetic material in R. prolixus bodies.Both VSM and behavioral results suggest that magnetosensitivity by a ferromagnetic hypothesis is not present in R. prolixus. Finally, our results indicate that the VSM magnetometer is a sensitive technique for detecting ferromagnetic material in insect tissues.

Figure optionsDownload as PowerPoint slideHighlights
► No response was found under an artificial field in a constant direction or rotated.
► Ferromagnetic material was detected in Apis mellifera but not in Rhodnius prolixus with VSM.
► There was no magnetosensitivity detected in R. prolixus based on a magnetite model.
► VSM methodology is sensitive to detect ferromagnetic material in insect tissues.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Insect Physiology - Volume 59, Issue 3, March 2013, Pages 345–350
نویسندگان
, , ,