کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
2853914 | 1572156 | 2014 | 5 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Reliability of ST-Segment Shifts in the Synthesized V3R-V5R Leads After Coronary Balloon Inflations During Percutaneous Coronary Intervention
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
موضوعات مرتبط
علوم پزشکی و سلامت
پزشکی و دندانپزشکی
کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله

چکیده انگلیسی
Obtaining a right-chest electrocardiogram is essential for diagnosing concomitant right ventricular infarction in patients with inferior wall acute myocardial infarctions. A software program to synthesize right-chest electrocardiographic waveforms from 12-lead electrocardiographic waveforms is available in Japan. However, its reliability has not been fully investigated. Accordingly, the aim of this study was to examine the reliability of ST-segment shifts in the synthesized V3R to V5R leads. ST-segment shifts in actual and synthesized V3R to V5R leads were compared during the last 10 seconds of 131 balloon inflations while performing elective percutaneous coronary intervention in 56 patients with coronary artery disease. ST-segment shifts in the actual and synthesized V3R, V4R, and V5R leads were correlated (r = 0.96, p <0.001, r = 0.94, p <0.001, and r = 0.91, p <0.001, respectively). A Bland-Altman analysis showed that the bias between ST-segment shifts in the actual and synthesized V3R to V5R leads was â3.1, â5.4, and â4.2 μV, respectively, while the limits of agreement between the ST-segment shifts in the actual and synthesized V3R to V5R leads were â59.2 to 52.9, â61.9 to 51.1, and â59.7 to 51.3 μV, respectively. The κ coefficients for ST-segment elevation of â¥50 and â¥100 μV in the actual and synthesized V3R, V4R, and V5R leads were 0.83 and 0.81, 0.66 and 0.83, and 0.57 and 0.80, respectively. In conclusion, these results indicate that ST-segment shifts in the synthesized V3R to V5R leads have acceptable reliability, suggesting that synthesized right-chest electrocardiography can be used to diagnose concomitant right ventricular infarction in patients with inferior wall acute myocardial infarctions.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The American Journal of Cardiology - Volume 114, Issue 8, 15 October 2014, Pages 1187-1191
Journal: The American Journal of Cardiology - Volume 114, Issue 8, 15 October 2014, Pages 1187-1191
نویسندگان
Akira MD, Kumie MD, Yukie MD, Shigeru MD, Kazuhiro MD, Hirofumi MD, Naohiko MD, PhD,