کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2853986 1572167 2014 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Device-Measured Physical Activity Versus Six-Minute Walk Test as a Predictor of Reverse Remodeling and Outcome After Cardiac Resynchronization Therapy for Heart Failure
ترجمه فارسی عنوان
دستگاه اندازه گیری فعالیت فیزیکی در مقابل شش دقیقه پیاده روی آزمون به عنوان پیش بینی کننده معکوس و نتیجه پس از درمان مجدد قلب برای درمان نارسایی قلبی
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
چکیده انگلیسی

Implanted devices can provide objective assessment of physical activity over prolonged periods. The purpose of this study was to investigate the prognostic value of device-measured physical activity data compared with a six-minute walk test (6MWT) in predicting clinical response to cardiac resynchronization therapy (CRT). This was a single-center study in which patients who underwent CRT for standard indications were evaluated. Daily physical activity and 6MWT were evaluated postimplant at 1, 3, and 6 months. The primary end point was a composite of heart failure hospitalization, transplant, left ventricular (LV) assist device, and all-cause death at 3 years. Echocardiographic response, defined as a ≥10% improvement in LV ejection fraction (LVEF), at 6 months was the secondary end point. About 164 patients were included: average age was 67.3 ± 12.9 years, 77% were men, baseline LVEF was 25% ± 7%. Kaplan-Meier curves showed superior freedom from the composite end point in the highest tertile of both 6MWT and physical activity compared with the lowest tertile (41 vs 23 cases, respectively, p <0.001) for 6MWT and for activity (22 vs 7 cases, respectively, p = 0.001). In an adjusted multivariate model, independent predictors of improved clinical outcome included 1-month physical activity (hazard ratio 0.546, 95% confidence interval [CI] 0.361 to 0.824, p = 0.004) and 6MWT (hazard ratio 0.581, 95% CI 0.425 to 0.795, p = 0.001). An additional hour of higher activity at 1 month translated to a 1.38 times (95% CI 1.075 to 1.753, p = 0.011) higher likelihood of improved echocardiographic response. In conclusion, device-based measures of physical activity may be useful in predicting echocardiographic reverse remodeling and long-term clinical outcome in patients receiving CRT.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The American Journal of Cardiology - Volume 113, Issue 9, 1 May 2014, Pages 1523–1528
نویسندگان
, , , , , , , , ,