کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2855055 1572176 2014 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Hemodynamic Impact and Outcome of Permanent Pacemaker Implantation Following Transcatheter Aortic Valve Implantation
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Hemodynamic Impact and Outcome of Permanent Pacemaker Implantation Following Transcatheter Aortic Valve Implantation
چکیده انگلیسی

Transcatheter aortic valve implantation (TAVI) frequently requires postprocedural permanent pacemaker (PPM) implantation. We evaluated clinical and hemodynamic impact of PPM after TAVI. Clinical and echocardiographic data were retrospectively analyzed in 230 consecutive patients who underwent TAVI and echocardiography at baseline and after 6 months. Echocardiographic parameters included left ventricular ejection fraction (LVEF), left ventricular (LV) stroke volume, early mitral velocity/annulus velocity ratio (E/e′), right ventricular index of myocardial performance, systolic pulmonary artery pressure (SPAP), and aortic, mitral, and tricuspid regurgitation grades. Clinical outcomes included 2-year survival and cardiovascular and PPM-related event-free survival. The Medtronic CoreValve and Edwards Sapien prosthesis were used in 201 and 29 patients, respectively. PPM was required in 58 patients (25.4%). Two-year and event-free survival rates were similar between patients with and without PPM. At 6 months, patients with PPM demonstrated attenuated improvement in LVEF (−0.9 ± 8.7% vs 2.3 ± 10.8%, respectively, p = 0.03) and LV stroke volume (−2 ± 16 vs 4 ± 10 ml/m2, respectively, p = 0.015), a trend toward smaller reduction in systolic pulmonary artery pressure (−1 ± 12 vs −6 ± 10 mm Hg, respectively, p = 0.09), and deterioration of right ventricular index of myocardial performance (−3 ± 17% vs 5 ± 26%, respectively, p = 0.05). The differences in post-TAVI aortic, mitral, and tricuspid regurgitation grades were insignificant. In conclusion, PPM implantation after TAVI is associated with reduced LVEF and impaired LV unloading. However, this unfavorable hemodynamic response does not affect the 2-year clinical outcome. The maintenance of clinical benefit appears to be driven by TAVI-related recovery of LV and right ventricular performance that mitigates unfavorable impact of PPM.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The American Journal of Cardiology - Volume 113, Issue 1, 1 January 2014, Pages 132–137
نویسندگان
, , , , , , , , , ,