Safety and Efficacy of the XIENCE V Everolimus-Eluting Stent Compared to First-Generation Drug-Eluting Stents in Contemporary Clinical Practice
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Safety and Efficacy of the XIENCE V Everolimus-Eluting Stent Compared to First-Generation Drug-Eluting Stents in Contemporary Clinical Practice
چکیده انگلیسی

Data from randomized clinical trials have shown the safety and efficacy of the XIENCE V in selected populations. However, limited data are available comparing the XIENCE V to the first-generation CYPHER sirolimus-eluting stent. This study aimed to assess the long-term safety and clinical efficacy of the XIENCE V everolimus-eluting stent compared to first-generation stents in an unselected patient population. This retrospective analysis included 6,069 patients treated with CYPHER, TAXUS, and XIENCE stents from 2003 to 2009 at our institution. The patients were followed up for ≥1 year after the index procedure. The baseline characteristics were generally comparable among the 3 groups, with the exception of a significantly greater prevalence of diabetes mellitus, systemic hypertension, and a history of angioplasty and coronary bypass surgery among the XIENCE patients. The XIENCE patients also had a twofold greater rate of type C lesions. One-year follow-up data were available for 82% of the patients. The 1-year major adverse cardiovascular events rate was 9.3% for the XIENCE stent versus 9.8% for the CYPHER stent and 11.5% for the TAXUS stent (p = 0.11). Mortality was lower in the XIENCE group than in the CYPHER and TAXUS groups (3.6% vs 4.9% vs 7.2%, respectively, p <0.001), and target lesion revascularization was similar (5.9% vs 5.2% vs 5.6%, respectively; p = 0.34). Stent thrombosis was lower in the XIENCE patients (0.2% vs 1.2% vs 0.7%, p = 0.007). In conclusion, in a contemporary United States clinical practice with an unselected patient population, use of the XIENCE V stent was associated with an improved safety profile and reduction of all-cause mortality and stent thrombosis compared to first-generation drug-eluting stents. The XIENCE V failed to demonstrate superiority for overall major adverse cardiovascular events, Q-wave myocardial infarction, and revascularization rates.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The American Journal of Cardiology - Volume 109, Issue 9, 1 May 2012, Pages 1288–1294
نویسندگان
, , , , , , , , , , ,