Impact of Stent Deployment Procedural Factors on Long-Term Effectiveness and Safety of Sirolimus-Eluting Stents (Final Results of the Multicenter Prospective STLLR Trial)
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Impact of Stent Deployment Procedural Factors on Long-Term Effectiveness and Safety of Sirolimus-Eluting Stents (Final Results of the Multicenter Prospective STLLR Trial)
چکیده انگلیسی

Drug-eluting stent failures were associated with various clinical factors. However, the clinical impact of stent deployment technique was unknown. This study was designed to evaluate the frequency and impact of suboptimal percutaneous coronary intervention on long-term outcomes of 1,557 patients treated with sirolimus-eluting stents (SESs) in 41 US hospitals. All steps of the interventional procedure were scrutinized by an independent core laboratory to determine the occurrence of geographic miss (GM). GM included longitudinal (LGM; injured or diseased segment not covered by SES) or axial GM (balloon-artery size ratio <0.9 or >1.3) mismatches. Patients with and without GM were stratified (GM vs no-GM group). Patients, investigators, and the independent clinical event adjudication committee were blind to study group assignments. The primary end point was 1-year target-vessel revascularization (TVR) rate. Incidences and predictors of GM and safety outcomes were secondary end points. GM occurred in 943 patients (66.5%): 47.6% had LGM, 35.2% had axial GM, and 16.5% had both. One-year TVR rates were 5.1% in the GM group versus 2.5% in the no-GM group (p = 0.025). TVR was 6.1% in the LGM versus 2.6% in the no-LGM subgroups (p = 0.001). The association of GM with 1-year TVR was independent of clinical or anatomic factors (hazard ratio 2.0, 95% confidence interval 1.0 to 4.02, p = 0.05). There was a 3-fold increase in myocardial infarction rates associated with GM (2.4% vs 0.8%; p = 0.04). In conclusion, GM occurred frequently during SES implantation and was associated with increased risk of TVR and myocardial infarction at 1 year. These results emphasized the need for improvement in contemporary percutaneous coronary intervention practices and technologies.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The American Journal of Cardiology - Volume 101, Issue 12, 15 June 2008, Pages 1704–1711