کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2910553 1175015 2011 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Balloon atrial septostomy: The oldest cardiac interventional procedure in Mansoura
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Balloon atrial septostomy: The oldest cardiac interventional procedure in Mansoura
چکیده انگلیسی

BackgroundBalloon atrial septostomy (BAS) was first described by Rashkind and Miller in 1966 and remains an important interventional procedure in the palliation of certain forms of congenital heart disease (CHD). Creating an atrial septa1 defect in patients with transposition of the great arteries (d-TGA) will enhance bidirectional mixing of the pulmonary and systemic venous blood, hence improving oxygen saturation. The aim of the work is to review and report our experience using balloon atrial septostomy in different CHD.MethodWe retrospectively reviewed the hospital records, echocardiographic and cardiac catheterization reports of patients subjected for BAS during the period from January 2001 till January 2010. One hundred and ninety two patients with CHD (78.5% d-TGA, 10% mitral atresia, 7.5% tricuspid atresia, and 4% hypoplastic left heart syndrome) underwent BAS. Their gestational age was 38.63 ± 1.48 weeks, postnatal age (median 3.5 days, range 1–54) and weight 3.08 ± 0.37 kg, 57.5% was male and 42.5% was female. All patients received PGE1 infusion before the procedure to maintain the ductal patency in a dose of 0.05–0.1 μg/kg/min.ResultsOne hundred twenty two procedures (63.5%) were done in neonatal intensive care at bedside and 70 procedures (36.5%) in the catheterization laboratory. General anesthesia was used in 31.3% of patients whereas conscious sedation was used in 68.7% of patients. Femoral access in 78% while umbilical access in 22%. Seven F sheath was used in 100% of case. The Miller catheter was used in 75% and a Z-5 septostomy catheter in 25% of cases. The diameter of the atrial communication increased from 2.75 ± 0.97 mm to 7.07 ± 0.79 mm (p < 0.0001). Oxygen saturations increased significantly from 65.38 ± 9.59% to 88.62 ± 3.13% (p < 0.0001). Mean pressure gradient for patients done in catheterization laboratory decreased from 4.1 ± 2.4 to 0.5 ± 1.1 mmHg (p < 0.0001). The number of septostomies required to achieve good results was 5.23 ± 1.20. No significant difference in oxygen saturation or the size of inter-atrial communication was observed between the two used balloons (p = 0.6).ConclusionBAS is safe and an effective palliative procedure for different CHD with good immediate results in our institution.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Egyptian Heart Journal - Volume 63, Issue 2, June 2011, Pages 125–129
نویسندگان
, , , , ,