کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2910810 1175029 2012 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Effect of isolated coronary artery ectasia on dispersion of P-wave and QT interval
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Effect of isolated coronary artery ectasia on dispersion of P-wave and QT interval
چکیده انگلیسی

BackgroundCoronary artery ectasia (CAE) is well-recognized, angiographic finding of abnormal coronary artery dilatation, and detected in 0.3–5.3% of angiographic studies. The gold standard for diagnosis this type of aneurysm is coronary angiography, which provides information about the size, sample, location and number of aneurysms. Despite growing prevalence in recent years, controversy still exists as to the pathogenetic mechanisms that underlie this entity. In this study we search the effect of isolated CAE on P-wave and QT interval dispersion.Patients and methodsTwenty patients (mean age: 60 ± 9.7 years) with isolated CAE (group I) were included in the study and 18 control subjects (group II) matched in sex and age. Both groups underwent a standard 12-lead surface electrocardiogram recorded at 50 mm/s. Maximal (P max) and minimal P-wave durations (P min) are measured. P dispersion (PD) was defined as the difference between P max and P min. QT interval was measured from the onset of the QRS complex to the end of the T-wave, defined as the return to the T–P isoelectric line. The mean of three consecutive intervals in each analyzable lead was taken for analysis. QT dispersion was defined as the difference between the longest and shortest QT intervals and the rate corrected with Bazett’s formula.ResultsP max (117.1 ± 4.6) and PD (34.2 ± 5.4) were significantly higher in ectatic patients (group I) than those of the control (group II) [P max (100.5 ± 5) and PD (18 ± 5.4)], while no significant difference between the two groups as regards P min.C QT duration (401 ± 4.4), QT dispersion (31.7 ± 3), and C QT dispersion (33.9 ± 3.3) were significantly higher in group I than those of group II [C QT duration (391.9 ± 2), QT dispersion (27.3 ± 1), and C QT dispersion (29 ± 0.9)]. While there were no statistically significant difference between the two groups as regards echo data (EDD, ESD, EF, LA, LVMI, and AO).ConclusionIsolated CAE were found to be associated with prolonged dispersion of P-wave and QT interval.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Egyptian Heart Journal - Volume 64, Issue 3, September 2012, Pages 121–125
نویسندگان
,