کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2922112 1175835 2013 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
New image processing and noise reduction technology allows reduction of radiation exposure in complex electrophysiologic interventions while maintaining optimal image quality: A randomized clinical trial
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
New image processing and noise reduction technology allows reduction of radiation exposure in complex electrophysiologic interventions while maintaining optimal image quality: A randomized clinical trial
چکیده انگلیسی

BackgroundDespite their carcinogenic potential, X-rays remain indispensable for electrophysiologic (EP) procedures.ObjectiveThe purpose of this study was to evaluate the dose reduction and image quality of a novel X-ray technology using advanced image processing and dose reduction technology in an EP laboratory.MethodsIn this single-center, randomized, unblinded, parallel controlled trial, consecutive patients undergoing catheter ablation for complex arrhythmias were eligible. The Philips Allura FD20 system allows switching between the reference (Allura Xper) and the novel X-ray imaging technology (Allura Clarity). Primary end-point was overall procedural patient dose, expressed in dose area product (DAP) and air kerma (AK). Operator dose, procedural success, and necessity to switch to higher dose settings were secondary end-points.ResultsA total of 136 patients were randomly assigned to the novel imaging group (n = 68) or the reference group (n = 68). Baseline characteristics were similar, except patients in the novel imaging group were younger (58 vs 65 years, P < .01). Median DAP and AK were 43% and 40% lower in the novel imaging group, respectively (P < .0001). A 50% operator dose reduction was achieved in the novel imaging group (P < .001). Fluoroscopy time, number of exposure frames, and procedure duration were equivalent between the two groups, indicating that the image quality was similarly adequate in both groups. Procedural success was achieved in 91% of patients in both groups; one pericardial tamponade occurred in the novel imaging group.ConclusionThe novel imaging technology, Allura Clarity, significantly reduces patient and operator dose in complex EP procedures while maintaining image quality.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Heart Rhythm - Volume 10, Issue 11, November 2013, Pages 1678–1682
نویسندگان
, , , , , , , ,