کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2925200 1175935 2008 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Detection of the diastolic pathway, circuit morphology, and inducibility of human postinfarction ventricular tachycardia from mapping in sinus rhythm
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Detection of the diastolic pathway, circuit morphology, and inducibility of human postinfarction ventricular tachycardia from mapping in sinus rhythm
چکیده انگلیسی

ObjectiveThe purpose of this study was to determine whether sinus rhythm activation maps could be used to detect the origin and characteristics of reentrant ventricular tachycardia in postinfarction patients.MethodsIn each of 11 post–myocardial infarction patients, unipolar electrograms were acquired at 256 virtual endocardial sites using noncontact mapping. Electrograms were marked for activation time and mapped on a three-dimensional grid. Spatial differences in sinus rhythm activation time were correlated to isthmus characteristics and to activation through the diastolic pathway during tachycardia on the basis of the presence of contiguous lines of slow conduction and block.ResultsTwenty tachycardia morphologies were analyzed. Fourteen sustained reentrant circuit morphologies occurred in nine patients, with dual morphologies having a shared isthmus occurring in five of nine patients. Dual morphologies were caused by changes in entrance-exit point location about a common isthmus. One transient circuit morphology of <10 beats occurred in three of nine patients also having sustained reentry. The estimated isthmus determined from sinus rhythm activation overlapped the diastolic pathway determined from tachycardia maps with 83.8% sensitivity and 89.2% specificity. The mean difference in sinus rhythm activation time across the isthmus border was larger in transient compared with sustained morphologies (32.8 ± 9.5 ms vs. 22.8 ± 1.8 ms), with smaller isthmus size (4.8 ± 1.1 cm2 vs. 10.0 ± 1.1 cm2; P < .05), narrower entrance-exit points (7.0 ± 1.5 mm vs. 9.3 ± 0.8 mm; P < .05), and greater activation time difference across them (16.3 ± 3.5 ms vs. 10.1 ± 1.0 ms; P < .05).ConclusionIn post–myocardial infarction patients, the reentry isthmus can be localized in the endocardial border zone from sinus rhythm activation maps. Nonsustained reentry occurs when isthmus size is small and entrance-exit points are narrow and more electrically discontinuous.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Heart Rhythm - Volume 5, Issue 7, July 2008, Pages 981–991
نویسندگان
, , , , , ,