کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2939816 1177004 2015 12 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Relation Between Bioresorbable Scaffold Sizing Using QCA-Dmax and Clinical Outcomes at 1 Year in 1,232 Patients From 3 Study Cohorts (ABSORB Cohort B, ABSORB EXTEND, and ABSORB II)
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Relation Between Bioresorbable Scaffold Sizing Using QCA-Dmax and Clinical Outcomes at 1 Year in 1,232 Patients From 3 Study Cohorts (ABSORB Cohort B, ABSORB EXTEND, and ABSORB II)
چکیده انگلیسی

ObjectivesThis study sought to investigate the clinical outcomes based on the assessment of quantitative coronary angiography–maximal lumen diameter (Dmax).BackgroundAssessment of pre-procedural Dmax of proximal and distal sites has been used for Absorb scaffold size selection in the ABSORB studies.MethodsA total of 1,248 patients received Absorb scaffolds in the ABSORB Cohort B (ABSORB Clinical Investigation, Cohort B) study (N = 101), ABSORB EXTEND (ABSORB EXTEND Clinical Investigation) study (N = 812), and ABSORB II (ABSORB II Randomized Controlled Trial) trial (N = 335). The incidence of major adverse cardiac events (MACE) (a composite of cardiac death, any myocardial infarction [MI], and ischemia-driven target lesion revascularization) was analyzed according to the Dmax subclassification of scaffold oversize group versus scaffold nonoversize group.ResultsOf 1,248 patients, pre-procedural Dmax was assessed in 1,232 patients (98.7%). In 649 (52.7%) patients, both proximal and distal Dmax values were smaller than the nominal size of the implanted scaffold (scaffold oversize group), whereas in 583 (47.3%) of patients, the proximal and/or distal Dmax were larger than the implanted scaffold (scaffold nonoversize group). The rates of MACE and MI at 1 year were significantly higher in the scaffold oversize group than in the scaffold nonoversize group (MACE 6.6% vs. 3.3%; log-rank p < 0.01, all MI: 4.6% vs. 2.4%; log-rank p = 0.04), mainly driven by a higher MI rate within 1 month post-procedure (3.5% vs. 1.9%; p = 0.08). The independent MACE determinants were both Dmax smaller than the scaffold nominal size (odds ratio [OR]: 2.13, 95% confidence interval [CI]: 1.22 to 3.70; p < 0.01) and the implantation of overlapping scaffolds (OR: 2.10, 95% CI: 1.17 to 3.80; p = 0.01).ConclusionsImplantation of an oversized Absorb scaffold in a relatively small vessel appears to be associated with a higher 1-year MACE rate driven by more frequent early MI. (ABSORB Clinical Investigation, Cohort B [ABSORB Cohort B], NCT00856856; ABSORB EXTEND Clinical Investigation [ABSORB EXTEND], NCT01023789; ABSORB II Randomized Controlled Trial [ABSORB II], NCT01425281)

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: JACC: Cardiovascular Interventions - Volume 8, Issue 13, November 2015, Pages 1715–1726
نویسندگان
, , , , , , , , , , , , ,