کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2940006 1177009 2015 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Plaque Characterization to Inform the Prediction and Prevention of Periprocedural Myocardial Infarction During Percutaneous Coronary Intervention : The CANARY Trial (Coronary Assessment by Near-infrared of Atherosclerotic Rupture-prone Yellow)
ترجمه فارسی عنوان
مشخصه پلاک برای اطلاع رسانی پیشگیری و پیشگیری از انفارکتوس میوکارد پروپروسیجار در مداخله عروق کرونر: آزمایش کانری (ارزیابی کرونری توسط نزدیک مادون قرمز از زرد ضایعه اتروسکلروزیس)
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
چکیده انگلیسی

ObjectivesThis study sought to determine whether pre–percutaneous coronary intervention (PCI) plaque characterization using near-infrared spectroscopy identifies lipid-rich plaques at risk of periprocedural myonecrosis and whether these events may be prevented by the use of a distal protection filter during PCI.BackgroundLipid-rich plaques may be prone to distal embolization and periprocedural myocardial infarction (MI) in patients undergoing PCI.MethodsPatients undergoing stent implantation of a single native coronary lesion were enrolled in a multicenter, prospective trial. Near-infrared spectroscopy and intravascular ultrasound were performed at baseline, and lesions with a maximal lipid core burden index over any 4-mm length (maxLCBI4mm) ≥600 were randomized to PCI with versus without a distal protection filter. The primary endpoint was periprocedural MI, defined as troponin or a creatine kinase-myocardial band increase to 3 or more times the upper limit of normal.ResultsEighty-five patients were enrolled at 9 U.S. sites. The median (interquartile range) maxLCBI4mm was 448.4 (274.8 to 654.4) pre-PCI and decreased to 156.0 (75.6 to 312.6) post-PCI (p < 0.0001). Periprocedural MI developed in 21 patients (24.7%). The maxLCBI4mm was higher in patients with versus without MI (481.5 [425.6 to 679.6] vs. 371.5 [228.9 to 611.6], p = 0.05). Among 31 randomized lesions with maxLCBI4mm ≥600, there was no difference in the rates of periprocedural MI with versus without the use of a distal protection filter (35.7% vs. 23.5%, respectively; relative risk: 1.52; 95% confidence interval: 0.50 to 4.60, p = 0.69).ConclusionsPlaque characterization by near-infrared spectroscopy identifies lipid-rich lesions with an increased likelihood of periprocedural MI after stent implantation, presumably due to distal embolization. However, in this pilot randomized trial, the use of a distal protection filter did not prevent myonecrosis after PCI of lipid-rich plaques.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: JACC: Cardiovascular Interventions - Volume 8, Issue 7, June 2015, Pages 927–936
نویسندگان
, , , , , , , , , , , , ,