کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2940095 1177016 2014 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
ABSORB Biodegradable Stents Versus Second-Generation Metal Stents : A Comparison Study of 100 Complex Lesions Treated Under OCT Guidance
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
ABSORB Biodegradable Stents Versus Second-Generation Metal Stents : A Comparison Study of 100 Complex Lesions Treated Under OCT Guidance
چکیده انگلیسی

ObjectivesThe aim of this study was to compare the acute performance of the PLLA ABSORB bioresorbable vascular scaffold (BVS) (Abbott Vascular, Santa Clara, California) with second-generation metal drug-eluting stents (DES) in complex coronary artery lesions.BackgroundThick polymer-based BVS have different mechanical properties than thin second-generation DES. Data on the acute performance of BVS are limited to simple coronary lesions treated in trials with strict inclusion criteria.MethodsFifty complex coronary lesions (all type American College of Cardiology/American Heart Association B2-C) treated with a BVS undergoing a final optical coherence tomography (OCT) examination were compared with an equal number of matched lesions treated with second-generation DES. The following stent performance indexes were assessed with OCT: mean and minimal area, residual area stenosis (RAS), incomplete strut apposition (ISA), tissue prolapse, eccentricity index, symmetry index, strut fracture, and edge dissection.ResultsOne hundred lesions from 73 patients were analyzed. A higher balloon diameter/reference vessel diameter ratio was used for predilation in the BVS group (p < 0.01). Most of the BVS and DES were post-dilated with short noncompliant (NC) balloons of similar diameter. OCT showed in the BVS group a higher tissue prolapse area (p = 0.08) and greater incidence of ISA at the proximal edge (p = 0.04) with no difference in the overall ISA. The RAS was 20.2% in the BVS group and 21.7% in the DES group (p = 0.32). There was no difference in the eccentricity index. The minimal and mean lumen areas were similar in the 2 groups. Two cases of strut fractures occurred after the BVS, whereas none was observed in the DES.ConclusionsBased on OCT, the BVS showed similar post-procedure area stenosis, minimal lumen area, and eccentricity index as second-generation DES. The different approach for lesion preparation and routine use of OCT guidance during BVS expansion may have contributed to these results.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: JACC: Cardiovascular Interventions - Volume 7, Issue 7, July 2014, Pages 741–750
نویسندگان
, , , , , , , , , , , , , ,