کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2940096 1177016 2014 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Direct Drug-Eluting Stenting to Reduce Stent Restenosis : A Randomized Comparison of Direct Stent Implantation to Conventional Stenting With Pre-Dilation or Provisional Stenting in Elective PCI Patients
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Direct Drug-Eluting Stenting to Reduce Stent Restenosis : A Randomized Comparison of Direct Stent Implantation to Conventional Stenting With Pre-Dilation or Provisional Stenting in Elective PCI Patients
چکیده انگلیسی

ObjectivesThe aim was to investigate whether a strategy of direct drug-eluting stent (DES) implantation without pre-dilation is associated with a reduced incidence of restenosis compared with CS with pre-dilation or provisional stenting (PS).BackgroundPrevious studies were performed comparing direct stenting (DS) with conventional stenting (CS) after pre-dilation; however, none of these in the DES era. Therefore, the STRESSED (direct Stenting To reduce REStenosis in Stent Era with Drug elution) study was designed and carried out.MethodsA total of 600 patients with angina pectoris or recent myocardial infarction were randomized to a DS, CS, or PS strategy. The primary endpoint was the mean minimal lumen diameter at 9-month follow-up angiography. Secondary endpoints were clinical procedural success defined as angiographic success without in-hospital major adverse cardiac events (MACE), and MACE at 9-month and 2-year follow-up.ResultsStent implantation in the DS group was 98%, 99% in the CS group, and 77% in the PS group. Percutaneous coronary intervention success was 99% in all groups. The minimal lumen diameter at 9-month follow-up was 2.12 ± 0.58 mm (DS), 2.17 ± 0.67 mm (CS), and 1.99 ± 0.69 mm (PS), p = 0.556 for comparison of DS with CS, p = 0.073 for comparison of DS with PS. The absolute difference was −0.05 (DS to CS), 95% confidence interval: −0.19 to −0.09, p = 0.48 and 0.13 (DS to PS), confidence interval: −0.02 to −0.27, p = 0.087. Restenosis was found in 3.4% (DS), 6.7% (CS), and 11.5% (PS), p = 0.025. At 9-month and 2-year follow-up, MACE occurred in 6.8% and 11.5% (DS), 4.6% and 10.3% (CS), and 7.6% and 13.8% (PS) (p = 0.439 and 0.536), respectively.ConclusionsDirect DES implantation compared with conventional DES implantation did not reduce restenosis. Provisional stenting, however, was associated with a higher rate of restenosis. This did not translate into a difference in the rate of MACE. (STRESSED study: direct Stenting To reduce REStenosis in Stent Era with Drug elution; ISRCTN41213536)

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: JACC: Cardiovascular Interventions - Volume 7, Issue 7, July 2014, Pages 751–758
نویسندگان
, , , , , , , , , , ,