کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2941001 1177050 2012 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Radiation Dose Reduction in the Invasive Cardiovascular Laboratory : Implementing a Culture and Philosophy of Radiation Safety
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Radiation Dose Reduction in the Invasive Cardiovascular Laboratory : Implementing a Culture and Philosophy of Radiation Safety
چکیده انگلیسی

ObjectivesThis paper investigates the effects of sustained practice and x-ray system technical changes on the radiation dose administered to adult patients during invasive cardiovascular procedures.BackgroundIt is desirable to reduce radiation dose associated with medical imaging to minimize the risk of adverse radiation effects to both patients and staff. Several clinical practice and technical changes to elevate radiation awareness and reduce patient radiation dose were implemented under the guidance of a cardiovascular invasive labs radiation safety committee. Practice changes included: intraprocedure radiation dose announcements; reporting of procedures for which the air-kerma exceeded 6,000 mGy, including procedure air-kerma in the clinical report; and establishing compulsory radiation safety training for fellows. Technical changes included establishing standard x-ray imaging protocols, increased use of x-ray beam spectral filters, reducing the detector target dose for fluoroscopy and acquisition imaging, and reducing the fluoroscopy frame rate to 7.5 s−1.MethodsPatient- and procedure-specific cumulative skin dose was calculated from air-kerma values and evaluated retrospectively over a period of 3 years. Data were categorized to include all procedures, percutaneous coronary interventions, coronary angiography, noncardiac vascular angiography and interventions, and interventions to treat structural heart disease. Statistical analysis was based on a comparison of the cumulative skin dose for procedures performed during the first and last quarters of the 3-year study period.ResultsA total of 18,115 procedures were performed by 27 staff cardiologists and 65 fellows-in-training. Considering all procedures, the mean cumulative skin dose decreased from 969 to 568 mGy (40% reduction) over 3 years.ConclusionsThis work demonstrates that a philosophy of radiation safety, implemented through a collection of sustained practice and x-ray system changes, can result in a significant decrease in the radiation dose administered to patients during invasive cardiovascular procedures.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: JACC: Cardiovascular Interventions - Volume 5, Issue 8, August 2012, Pages 866–873
نویسندگان
, , , , , ,