کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2941296 1177064 2010 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Long-Term Impact of Routinely Detected Early and Late Incomplete Stent Apposition : An Integrated Intravascular Ultrasound Analysis of the TAXUS IV, V, and VI and TAXUS ATLAS Workhorse, Long Lesion, and Direct Stent Studies
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Long-Term Impact of Routinely Detected Early and Late Incomplete Stent Apposition : An Integrated Intravascular Ultrasound Analysis of the TAXUS IV, V, and VI and TAXUS ATLAS Workhorse, Long Lesion, and Direct Stent Studies
چکیده انگلیسی

ObjectivesWe sought to determine the 2-year impact of early and late-acquired incomplete stent apposition (ISA) on clinical events.BackgroundThe late clinical impact of early or late-acquired ISA in bare-metal stents (BMS) and TAXUS stents (Boston Scientific, Natick, Massachusetts) is debatable.MethodsWe evaluated 1,580 patients enrolled in the intravascular ultrasound (IVUS) substudies of TAXUS IV, V, VI and TAXUS-ATLAS WH, LL, and DS trials.ResultsThere were 96 cases of early ISA in 26 (7.2%) BMS patients, 35 (9.7%) TAXUS Express patients (p = 0.28 vs. BMS), and 35 (7.3%) TAXUS Liberté patients (p = 0.21 vs. TAXUS Express, and p = 1.00 vs. BMS). Major adverse cardiovascular events were similar at 9 months in patients with early ISA versus control subjects with no ISA for BMS (3.8% vs. 15.2%, p = 0.13) and for TAXUS (11.6% vs. 8.8%, p = 0.45). There was no impact of early ISA on stent thrombosis. At 9-month follow-up, there were 36 cases of late-acquired ISA in 7 (2.7%) BMS patients, 17 (3.1%) patients with TAXUS slow-release (TAXUS Express or TAXUS Liberté), and 12 (15.4%) patients receiving TAXUS moderate-release. Over 2 ensuing years, major adverse cardiovascular events were similar in patients with late-acquired ISA versus control subjects with no ISA for BMS (14.3% vs. 7.9%, p = 0.54), TAXUS (overall, 8.3% vs. 8.1% p = 0.87), or TAXUS slow-release formulation (0% vs. 7.9%, p = 0.28). There was no impact of late-acquired ISA on stent thrombosis.ConclusionsNeither routinely detected acute ISA nor routinely detected late-acquired ISA in BMS or TAXUS patients was associated with adverse clinical events over long-term follow-up.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: JACC: Cardiovascular Interventions - Volume 3, Issue 5, May 2010, Pages 486–494
نویسندگان
, , , , , , , , , , ,