کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2941477 1177072 2009 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Feasibility, Safety, and Efficacy of a Novel Polymeric Pimecrolimus-Eluting Stent: Traditional Pre-Clinical Safety End Points Failed to Predict 6-Month Clinical Angiographic Results
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Feasibility, Safety, and Efficacy of a Novel Polymeric Pimecrolimus-Eluting Stent: Traditional Pre-Clinical Safety End Points Failed to Predict 6-Month Clinical Angiographic Results
چکیده انگلیسی

ObjectivesThe aim of this study was to determine the safety and efficacy of a novel pimecrolimus-eluting stent in a porcine coronary model and in a phase I clinical trial.BackgroundRapamycin- and paclitaxel-eluting stents reduce the need for repeat intervention by limiting neointimal hyperplasia but might cause delayed healing, pre-disposing patients to late stent thrombosis. Because inflammation plays a key role in restenosis, pimecrolimus, an anti-inflammatory drug, might reduce restenosis without adversely affecting re-endothelialization.MethodsWe evaluated a novel polymeric pimecrolimus-eluting stent covered with a thin parylene C diffusion barrier in a porcine coronary model and in a phase I human clinical trial. The clinical study was a prospective, nonrandomized, first-in-human hypothesis-generating study that enrolled 15 patients who had a single de novo native coronary stenosis.ResultsAt 28 days and 3 months in the porcine model, histopathologic indicators predicted safety and biocompatibility when stents coated with polymer only, drug only, and 2 drug-polymer formulations were compared with bare-metal stents (BMS). In the phase I clinical trial, 15 patients had successful implantation of pimecrolimus-eluting stents. By 6 months, no patient suffered death, myocardial infarction, or stent thrombosis. However, the angiographic restenosis (61%), mean late loss (1.44 mm), and repeat target lesion revascularization (53%) were significantly higher than historical BMS controls. Whereas the primary end point was percent volume obstruction, restenosis was so severe that operators performed intravascular ultrasound examination in only 6 patients.ConclusionsPimecrolimus-eluting stents induced an exaggerated neointimal hyperplasia at 6 months in comparison with historical controls.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: JACC: Cardiovascular Interventions - Volume 2, Issue 10, October 2009, Pages 1017–1024
نویسندگان
, , , , , , , ,