کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2941887 1177090 2010 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A Novel Paclitaxel-Eluting Stent With an Ultrathin Abluminal Biodegradable Polymer : 9-Month Outcomes With the JACTAX HD Stent
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
A Novel Paclitaxel-Eluting Stent With an Ultrathin Abluminal Biodegradable Polymer : 9-Month Outcomes With the JACTAX HD Stent
چکیده انگلیسی

ObjectivesThe JACTAX HD trial (“JACTAX” Trial Drug Eluting Stent Trial) evaluated the safety and clinical performance of a novel JACTAX HD (Boston Scientific Corporation, Natick, Massachusetts) paclitaxel-eluting stent (PES) in de novo coronary lesions.BackgroundThe JACTAX HD (Boston Scientific) stent consists of a pre-crimped bare-metal Liberté (Boston Scientific) stent coated on its abluminal aspect with an ultrathin (<1 μm) 1/1 mixture of biodegradable polylactide polymer and paclitaxel applied as discrete microdots (nominal totals of 9.2 μg each of polymer and paclitaxel per 16-mm stent).MethodsIn this prospective, single-arm, multicenter, first-human-use study (n = 103), the primary end point of 9-month major adverse cardiac events (MACE) (cardiac death, myocardial infarction, ischemia-related target vessel revascularization) was compared with an objective performance criterion (OPC) of 17% (11% MACE based on TAXUS ATLAS [TAXUS Liberté-SR Stent for the Treatment of de Novo Coronary Artery Lesions] trial results plus a pre-specified noninferiority margin of 6%).ResultsThe composite primary end point occurred in 7.8% of JACTAX HD patients with an upper 1-sided 95% confidence limit of 13.6%, thus meeting the pre-specified criteria for noninferiority. There was no death, Q-wave myocardial infarction, or stent thrombosis through 9 months. In-stent late loss was 0.33 ± 0.45 mm, with an in-stent binary restenosis of 5.2% and net volume obstruction by intravascular ultrasound of 11.4 ± 11.2%.ConclusionsThe JACTAX HD stent with an abluminal biodegradable polymer showed 9-month MACE, in-stent late loss, restenosis, and net volume obstruction comparable to that observed with the TAXUS Liberté (Boston Scientific) stent coated with a conformal durable polymer. Further studies are underway to better evaluate the potential of this new PES design, which might allow for more rapid endothelialization and improved vessel healing. (“JACTAX” Trial Drug Eluting Stent Trial; NCT00754728)

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: JACC: Cardiovascular Interventions - Volume 3, Issue 4, April 2010, Pages 431–438
نویسندگان
, , , , , , ,