کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2941965 1177094 2010 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Correlation of Device Landing Zone Calcification and Acute Procedural Success in Patients Undergoing Transcatheter Aortic Valve Implantations With the Self-Expanding CoreValve Prosthesis
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Correlation of Device Landing Zone Calcification and Acute Procedural Success in Patients Undergoing Transcatheter Aortic Valve Implantations With the Self-Expanding CoreValve Prosthesis
چکیده انگلیسی

ObjectivesThe aim of this study was to assess the influence of amount and distribution of calcifications of the aortic valve and the left ventricular outflow tract on the acute procedural outcome of patients undergoing transcatheter aortic valve implantation (TAVI).BackgroundTranscatheter aortic valve implantation is a new percutaneous technique especially for elderly, high-risk patients with significant aortic valve stenosis (AS). After TAVI, post-interventional paravalvular aortic regurgitations (PAR) can occur, which is believed to be related partially to valve calcifications.MethodsWe prospectively analyzed 100 symptomatic patients with severe AS scheduled for TAVI with the CoreValve ReValving (Medtronic, Minneapolis, Minnesota) prosthesis. In all patients, a native and contrast-enhanced multislice cardiac computed tomography was performed pre-interventionally. Calcification load of the valve and the adjacent outflow tract was estimated by the Agatston Score (AgS), and the amount and distribution of calcification was semi-quantitatively assessed and graded on a 1 to 4 scale (device “landing zone” calcification score [DLZ-CS]). Aortography was performed to evaluate the PAR pre-interventionally, after initial device release (PAR0) and after termination of the procedure (PAR1). Transthoracic echocardiography was performed 2 weeks after implantation (PAR2).ResultsThe AgS and DLZ-CS showed a significant correlation with the grade of PAR0 (AgS: r = 0.329, p = 0.001; DLZ-CS: r = 0.356, p < 0.001), PAR1 (AgS: r = 0.254, p = 0.011; DLZ-CS: r = 0.240, p = 0.016), and PAR2 (AgS: r = 0.341, p = 0.001; DLZ-CS: r = 0.300, p = 0.002). Both scores (AgS and DLZ-CS) showed a significant positive correlation (r = 0.858, p < 0.001).ConclusionsCalcification in the CoreValve device “landing zone” shows a significant positive correlation to PAR after TAVI. Furthermore, the need for “second maneuvers” (i.e., post-dilation after initial device release) can be predicted by these calcification scores (AgS and DLZ-CS).

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: JACC: Cardiovascular Interventions - Volume 3, Issue 2, February 2010, Pages 233–243
نویسندگان
, , , , , , , ,