Anti–Factor Xa and Activated Partial Thromboplastin Time Measurements for Heparin Monitoring in Mechanical Circulatory Support
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Anti–Factor Xa and Activated Partial Thromboplastin Time Measurements for Heparin Monitoring in Mechanical Circulatory Support
چکیده انگلیسی

ObjectivesThis study investigated the relationship between anti–factor Xa (anti-FXa) and activated partial thromboplastin time (aPTT) for monitoring intravenous unfractionated heparin (IV-UFH) in patients with continuous-flow left ventricular assist devices (CF-LVADs).BackgroundCF-LVADs have become mainstream therapy for patients with advanced heart failure. Thromboembolic events, device thrombosis, and bleeding continue to be a challenge with this technology. Adequate anticoagulation is required to prevent these adverse events.MethodsA prospective study of consecutive patients implanted with a CF-LVAD was conducted. Paired samples were considered concordant if aPTT values fell into expected ranges for subtherapeutic, therapeutic, and supratherapeutic anti-FXa levels. Heparin dosing was on the basis of anti-Xa levels.ResultsA total of 340 paired values from 38 patients were evaluated. Anti-FXa and aPTT were discordant in 253 samples (74.4%), with a high degree of variability in aPTT for any given anti-FXa level (r2 = 0.57). Results were discordant in 104 samples (63.8%) from patients undergoing bridging therapy with warfarin and in 149 samples (84.2%) from patients with device obstruction and/or hemolysis (p < 0.001). The most common pattern of discordance was a supratherapeutic aPTT value despite a therapeutic anti-FXa level (49.1% for bridging vs. 75.8% for device obstruction and/or hemolysis; p < 0.001).ConclusionsLevels of aPTT were disproportionately prolonged relative to the corresponding anti-FXa levels in CF-LVAD patients, particularly those with device obstruction. Hemolysis and warfarin administration may falsely elevate aPTT, resulting in overestimation of heparin concentration and under-anticoagulation. Use of aPTT and anti-FXa to guide heparin therapy may lead to different estimates of heparin concentration in the same patient.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: JACC: Heart Failure - Volume 3, Issue 4, April 2015, Pages 314–322
نویسندگان
, , , , , , , , , ,