کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2944507 1577086 2014 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Association Between Frequency of Atrial and Ventricular Ectopic Beats and Biventricular Pacing Percentage and Outcomes in Patients With Cardiac Resynchronization Therapy
ترجمه فارسی عنوان
ارتباط بین فراوانی ضایعات بی حدی دهلیزی و بطنی و درصد پروتکل و نتایج پیگیری دو طرفه در بیمارانی که دارای درمان مجدد قلب هستند
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
چکیده انگلیسی

BackgroundA high percentage of biventricular pacing is required for optimal outcome in patients treated with cardiac resynchronization therapy (CRT), but the influence of ectopic beats on the success of biventricular pacing has not been well established.ObjectivesThis study sought to determine if increased ectopic beats reduce the chance of high biventricular pacing percentage and are associated with subsequent adverse outcomes.MethodsFrom the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy), 801 patients with an implanted CRT-defibrillator device with data available on biventricular pacing percentage and pre-implantation 24-h Holter recordings were included. Using logistic regression, we estimated the influence of ectopic beats on the percentage of biventricular pacing. Reverse remodeling was measured as reductions in atrial and left ventricular end-systolic volumes (LVESV) at 1 year. Cox models were used to assess the influence of ectopic beats on the outcomes of heart failure (HF) or death, ventricular tachyarrhythmias (VTAs), and death.ResultsIn the pre-implantation Holter recording, ectopic beats accounted for a mean 3.2 ± 5.5% of all beats. The probability of subsequent low biventricular pacing percentage (<97%) was increased 3-fold (odds ratio: 3.37; 95% confidence interval: 1.74 to 6.50; p < 0.001) in patients with 0.1% to 1.5% ectopic beats and 13-fold (odds ratio: 13.42; 95% confidence interval: 7.02 to 25.66; p < 0.001) in patients with >1.5% ectopic beats compared with those with <0.1% ectopic beats. Patients with ≥0.1% ectopic beats had significantly less reverse remodeling (percent reduction in LVESV 31 ± 15%) than patients with <0.1% ectopic beats (percent reduction in LVESV 39 ± 14%; p < 0.001). The risk of HF/death and VTA was increased significantly in those with 0.1% to 1.5% ectopic beats (hazard ratio: 3.13 and 1.84, respectively) and for >1.5% ectopic beats (hazard ratio: 2.38 and 2.74, respectively).ConclusionsRelatively low frequencies of ectopic beats (≥0.1%) dramatically increase the probability of low biventricular pacing (<97%), with reduced CRT efficacy by less reverse remodeling and higher risk of HF/death and VTA. This supports pre-implantation Holter monitoring of patients selected for CRT for optimal outcome. (MADIT-CRT: Multicenter Automatic Defibrillator Implantation With Cardiac Resynchronization Therapy; NCT00180271)

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of the American College of Cardiology - Volume 64, Issue 10, 9 September 2014, Pages 971–981
نویسندگان
, , , , , , , , , , , , ,