Early Anticoagulation of Bioprosthetic Aortic Valves in Older Patients : Results From the Society of Thoracic Surgeons Adult Cardiac Surgery National Database
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Early Anticoagulation of Bioprosthetic Aortic Valves in Older Patients : Results From the Society of Thoracic Surgeons Adult Cardiac Surgery National Database
چکیده انگلیسی

ObjectivesThe aim of this study was to evaluate the risks and benefits of short-term anticoagulation in patients receiving aortic valve bioprostheses.BackgroundPatients receiving aortic valve bioprostheses have an elevated early risk of thromboembolic events; however, the risks and benefits of short-term anticoagulation have been debated with limited evidence.MethodsOur cohort consisted of 25,656 patients ≥65 years of age receiving aortic valve bioprostheses at 797 hospitals within the Society of Thoracic Surgeons Adult Cardiac Surgery Database (2004 to 2006). The associated 3-month incidences of death or readmission for embolic (cerebrovascular accident, transient ischemic attack, and noncerebral arterial thromboembolism) or bleeding events were compared across discharge anticoagulation strategies with propensity methods.ResultsIn this cohort (median age, 77 years), the 3 most common discharge anticoagulation strategies included: aspirin-only (49%), warfarin-only (12%), and warfarin plus aspirin (23%). Among those receiving aspirin-only, 3-month adverse events were low (death, 3.0%; embolic events, 1.0%; bleeding events, 1.0%). Relative to aspirin-only, those treated with warfarin plus aspirin had a lower adjusted risk of death (relative risk [RR]: 0.80, 95% confidence interval [CI]: 0.66 to 0.96) and embolic event (RR: 0.52, 95% CI: 0.35 to 0.76) but a higher risk of bleeding (RR: 2.80, 95% CI: 2.18 to 3.60). Relative to aspirin-only, warfarin-only patients had a similar risk of death (RR: 1.01, 95% CI: 0.80 to 1.27), embolic events (RR: 0.95, 95% CI: 0.61 to 1.47), and bleeding (RR: 1.23, 95% CI: 0.85 to 1.79). These results were generally consistent across patient subgroups.ConclusionsDeath and embolic events were relatively rare in the first 3 months after bioprosthetic aortic valve replacement. Compared with aspirin-only, aspirin plus warfarin was associated with a reduced risk of death and embolic events, but at the cost of an increased bleeding risk.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of the American College of Cardiology - Volume 60, Issue 11, 11 September 2012, Pages 971–977
نویسندگان
, , , , , , , ,