کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2947396 1577206 2012 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
First Results of the DEB-AMI (Drug Eluting Balloon in Acute ST-Segment Elevation Myocardial Infarction) Trial : A Multicenter Randomized Comparison of Drug-Eluting Balloon Plus Bare-Metal Stent Versus Bare-Metal Stent Versus Drug-Eluting Stent in Primary
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
First Results of the DEB-AMI (Drug Eluting Balloon in Acute ST-Segment Elevation Myocardial Infarction) Trial : A Multicenter Randomized Comparison of Drug-Eluting Balloon Plus Bare-Metal Stent Versus Bare-Metal Stent Versus Drug-Eluting Stent in Primary
چکیده انگلیسی

ObjectivesThe goal of this study was to compare angiographic, intravascular imaging, and functional parameters, as well as the clinical outcomes of patients treated with drug-eluting balloon (DEB) plus bare-metal stent (BMS) versus BMS versus drug-eluting stent (DES) for ST-segment elevated acute myocardial infarction (STEMI).BackgroundConcerns remain regarding the long-term safety of DES in STEMI. DEB could provide an attractive alternative in order to achieve potentially similar effectiveness but limiting the long-term hazards related to late-acquired stent malapposition and thus stent thrombosis.MethodsIn this randomized, international, 2-center, single-blinded, 3-arm study, STEMI patients were randomly assigned to group A: BMS; group B: DEB plus BMS; or group C: DES after successful thrombus aspiration. The primary endpoint was 6-month angiographic in-stent late-luminal loss. Secondary endpoints were in-stent binary restenosis, major adverse cardiac events (MACE: cardiac death, myocardial infarction, target vessel revascularization). In a subgroup of patients, stent (mal)apposition (by optical coherence tomography) and endothelial function (by acetylcholine infusion) was assessed.ResultsOverall, 150 patients were randomized. Procedural success was achieved in 96.7%. In groups A, B, and C, respectively, late-luminal loss was 0.74 ± 0.57 mm, 0.64 ± 0.56 mm, and 0.21 ± 0.32 mm (p < 0.01); binary restenosis was 26.2%, 28.6%, and 4.7% (p = 0.01); and MACE rates were 23.5%, 20.0%, and 4.1% (p = 0.02), respectively. The median percentage [25th to 75th interquartile range] of uncovered and malapposed stent struts per lesion was 0 [0 to 0.35], 2.84 [0 to 6.63], and 5.21 [3.25 to 14.5] (p < 0.01). Significant paradoxical vasoconstriction was seen in groups B and C.ConclusionsIn STEMI patients, DEB followed by BMS implantation failed to show angiographic superiority to BMS only. Angiographic results of DES were superior to both BMS and DEB. Moreover, DEB before implantation induced more uncovered and malapposed stent struts than BMS, but less than after DES. (Drug-Eluting Balloon in Acute Myocardial Infarction [DEB-AMI]; NCT00856765)

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of the American College of Cardiology - Volume 59, Issue 25, 19–26 June 2012, Pages 2327–2337
نویسندگان
, , , , , , , , , , ,