کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2947590 1577223 2012 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Bioprosthetic Tricuspid Valve Regurgitation Associated With Pacemaker or Defibrillator Lead Implantation
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Bioprosthetic Tricuspid Valve Regurgitation Associated With Pacemaker or Defibrillator Lead Implantation
چکیده انگلیسی

ObjectivesThe goal of this study was to determine the impact of transvenous pacemaker and defibrillator leads on the incidence of bioprosthetic tricuspid valve (BTV) regurgitation compared with BTV patients without a transvalvular lead.BackgroundAlthough concern has been raised regarding the potential deleterious effect of permanent transvenous device leads on BTV function, little is known about the incidence of prosthetic tricuspid regurgitation (TR) after lead placement.MethodsA retrospective review of 58 patients who underwent BTV implantation and subsequently required endocardial pacemaker (n = 52) or defibrillator (n = 6) lead implantation across the BTV was conducted. Patient and prosthesis characteristics, lead type, and clinical events were collected. The incidence and severity of prosthetic TR, determined by Doppler echocardiography, was compared with 265 consecutive patients who underwent BTV implantation without undergoing subsequent transvalvular device lead implantation.ResultsOver a mean follow-up of 25 months, in 5 patients (9%) with a transvalvular lead significant (moderate or greater) prosthetic TR developed compared with 12 patients (5%) in the control group (p = 0.20). Kaplan-Meier analysis revealed no significant difference in the incidence of TR in BTV patients with and without transvalvular leads (p = 0.45). Significant prosthetic TR in patients with and without a transvalvular lead more commonly occurred 2 years or later after lead or BTV implantation (4 of 5, 80% and 10 of 12, 83%, respectively).ConclusionsTransvalvular device lead implantation in BTV patients was not associated with an increased incidence of significant prosthetic TR (p = 0.45). Based on these data, transvalvular lead implantation appears to be an acceptable approach for patients with a BTV who require permanent pacemaker or defibrillator placement.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of the American College of Cardiology - Volume 59, Issue 9, 28 February 2012, Pages 813–818
نویسندگان
, , , , , , ,