کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2948460 1577272 2011 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Stent Thrombosis and Bleeding Complications After Implantation of Sirolimus-Eluting Coronary Stents in an Unselected Worldwide Population : A Report From the e-SELECT (Multi-Center Post-Market Surveillance) Registry
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Stent Thrombosis and Bleeding Complications After Implantation of Sirolimus-Eluting Coronary Stents in an Unselected Worldwide Population : A Report From the e-SELECT (Multi-Center Post-Market Surveillance) Registry
چکیده انگلیسی

ObjectivesThe aim of this study was to ascertain the 1-year incidence of stent thrombosis (ST) and major bleeding (MB) in a large, unselected population treated with sirolimus-eluting stents (SES).BackgroundStent thrombosis and MB are major potential complications of drug-eluting stent implantation. Their relative incidence and predisposing factors among large populations treated worldwide are unclear.MethodsThe SES were implanted in 15,147 patients who were entered in a multinational registry. We analyzed the incidence of: 1) definite and probable ST as defined by the Academic Research Consortium; and 2) MB, with the STEEPLE (Safety and efficacy of Enoxaparin in PCI) definition, together with their relation to dual antiplatelet therapy (DAPT) and to 1-year clinical outcomes.ResultsThe mean age of the sample was 62 ± 11 years, 30.4% were diabetic, 10% had a Charlson comorbidity index ≥3, and 44% presented with acute coronary syndrome or myocardial infarction. At 1 year, the reported compliance with DAPT as recommended by the European Society of Cardiology guidelines was 86.3%. Adverse event rates were: ST 1.0%, MB 1.0%, mortality 1.7%, myocardial infarction 1.9%, and target lesion revascularization 2.3%. Multivariate analysis identified 9 correlates of ST and 4 correlates of MB. Advanced age and a high Charlson index were associated with an increased risk of both ST and MB. After ST, the 7-day and 1-year all-cause mortality was 30% and 35%, respectively, versus 1.5% and 10% after MB. Only 2 of 13,749 patients (0.015%) experienced both MB and ST during the entire 1-year follow-up period.ConclusionsIn this worldwide population treated with ≥1 SES, the reported compliance with DAPT was good, and the incidence of ST and MB was low. Stent thrombosis and MB very rarely occurred in the same patient. (The e-SELECT Registry: a Multicenter Post-Market Surveillance; NCT00438919)

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of the American College of Cardiology - Volume 57, Issue 13, 29 March 2011, Pages 1445–1454
نویسندگان
, , , , , , , , , , , , , , ,