کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2948715 1577290 2010 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Anatomic and Procedural Predictors of Paravalvular Aortic Regurgitation After Implantation of the Medtronic CoreValve Bioprosthesis
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Anatomic and Procedural Predictors of Paravalvular Aortic Regurgitation After Implantation of the Medtronic CoreValve Bioprosthesis
چکیده انگلیسی

ObjectivesThe purpose of this study was to determine the predictors of aortic regurgitation (AR) after transcatheter aortic valve implantation (TAVI).BackgroundTAVI has been associated with a high rate of paravalvular regurgitation, usually mild. Nevertheless, moderate to severe regurgitations still occur and may have negative clinical consequences.MethodsFifty patients with severe aortic stenosis were recruited and underwent successful TAVI with the Medtronic CoreValve bioprosthesis through the transfemoral route. The end point of this study is the early occurrence of significant AR, defined as the occurrence of grade II or more AR by post-procedural aortography.ResultsThe study population's mean age was 80.5 ± 7.9 years, with a mean aortic valve area of 0.64 ± 0.17 cm2. Post-procedural AR was absent in 3 patients and was grade I in 27 patients, grade II in 13 patients, and grade III in 7 patients. Using univariate analysis, the chance of significant AR increased with increasing angle of left ventricular outflow tract to ascending aorta (∠LVOT-AO) (odds ratio: 1.24, p < 0.001). For the depth of the device in relation to the noncoronary cusp, there was a minimum chance of AR corresponding to depth = 9.5 mm (odds ratio: 1.1, p = 0.01). Using multivariate analysis, we found a greater chance of significant AR with a greater angle (odds ratio: 1.24, p = 0.001), and that the chance of significant AR is a minimum when depth of the device in relation to the noncoronary cusp is ∼10 mm (odds ratio: 1.1, p = 0.024). A predictive model was generated, and if 2 ×∠LVOT-AO + (depth to noncoronary cusp − 10)2≥50, the likelihood of occurrence of significant AR could be predicted with a sensitivity of 85% and a specificity of 87%.ConclusionsThe occurrence of significant AR after TAVI can be predicted by anatomic and procedural variables. A model such as that presented can be used to select suitable patients for this procedure and guide operators during implantation of the device.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of the American College of Cardiology - Volume 56, Issue 20, 9 November 2010, Pages 1623–1629
نویسندگان
, , , , , , ,