کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2948780 1577249 2011 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Dual-Chamber Implantable Cardioverter-Defibrillator Selection Is Associated With Increased Complication Rates and Mortality Among Patients Enrolled in the NCDR Implantable Cardioverter-Defibrillator Registry
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Dual-Chamber Implantable Cardioverter-Defibrillator Selection Is Associated With Increased Complication Rates and Mortality Among Patients Enrolled in the NCDR Implantable Cardioverter-Defibrillator Registry
چکیده انگلیسی

ObjectivesThe aim of this study was to compare single- versus dual-chamber implantable cardioverter-defibrillator (ICD) implantation and complication rates in a large, real-world population.BackgroundThe majority of patients enrolled in ICD efficacy trials received single-chamber devices. Although dual-chamber ICDs offer theoretical advantages over single-chamber defibrillators, the clinical superiority of dual-chamber models has not been conclusively proven, and they may increase complications.MethodsThe National Cardiovascular Data Registry ICD Registry was used to examine the association between baseline characteristics and device selection in 104,049 patients receiving single- and dual-chamber ICDs between January 1, 2006, and December 31, 2007. A longitudinal cohort design was then used to determine in-hospital complication rates.ResultsDual-chamber devices were implanted in 64,489 patients (62%). Adverse events were more frequent with dual-chamber than with single-chamber device implantation (3.17% vs. 2.11%, p < 0.001), as was the rate of in-hospital mortality (0.40% vs. 0.23%, p < 0.001). After adjusting for demographics, medical comorbidities, diagnostic test data, and ICD indication, the odds of any complication (odds ratio: 1.40; 95% confidence interval: 1.28 to 1.52; p < 0.001) and in-hospital mortality (odds ratio: 1.45; 95% confidence interval: 1.20 to 1.74; p < 0.001) were increased with dual-chamber versus single-chamber ICD implantation.ConclusionsIn this large, multicenter cohort of patients, dual-chamber ICD use was common. Dual-chamber device implantation was associated with increases in periprocedural complications and in-hospital mortality compared with single-chamber defibrillator selection.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of the American College of Cardiology - Volume 58, Issue 10, 30 August 2011, Pages 1007–1013
نویسندگان
, , , , , ,